Make the electrical connections and connect
the air outlet pipe; place the ceiling-mounted
hood into the niche, by inserting the threaded
bars into the holes (Fig.6); the outer edge of
the hood needs to be perfectly flush with the
false ceiling. Insert the plates and nuts pro-
vided into the threaded bars, making sure to
tighten them securely (Fig. 7); refit the grease
filters and filter cover panels.
E200/150 – E200/110 – E205/110 V1100
WITH INTERNAL MOTOR
With Internal motor models, the same instal-
lation procedure as for the external motor
version (EM) can be followed, but with some
differences.
Remove the motor fixing screws ,pull the mo-
tor out, rotate it and then insert it in the out-
let hole just opened and fix it by using the
screws previously removed.
Unused holes must be closed with the suit-
able plug.
Carry out the installation as shown for the
external motor version, but taking into ac-
count the details above.
E210/150 V1350 – E210/110 V110 - E290/90
V1350 (internal motor)
Fit a false ceiling with an opening that has the
following dimensions:
E210/150 V1350: 1465x965 mm with a min-
imum distance of 330 mm between the ceil-
ing and the false ceiling;
E210/110 V1100: 1065x665 mm with a min-
imum distance of 330 mm between the ceil-
ing and the false ceiling
E290/90 V1350: 865x405 mm with a mini-
mum distance of 330 mm between the ceiling
and the false ceiling
It is possible to select the side of the cooker
hood where the air suctioned can be dis-
charged, as follows:
Remove the eight fixing screws of the suc-
tioning unit shown in fig. 11, pull the suc-
tioning unit out by disconnecting the elec-
tric connector, remove the cover of the air
out-let hole you want to use and place the
suctioning unit. Restore the electric connec-
tion and secure the suctioning unit with the
screws previously removed. Refit the cover on
the unused air out-let hole. Carry out the in-
stallation following the procedure shown for
E200/150, E200/110 and E280/90 models.
E210/150 V1350 – E210/110 V1350 WITH
EXTERNAL MOTOR
Fit a false ceiling with an opening that has the
following dimensions:
E210/150 V1350: 1465x965 mm with a min-
imum distance of 330 mm between the ceil-
ing and the false ceiling;
E210/110 V1350: 1065x665 mm with a mini-
mum distance of 330 mm between the ceiling
and the false ceiling.
It is possible to select the side of the cooker
hood where the air suctioned can be dis-
charged, as follows:
Remove the eight fixing screws of the air-
outlet flange shown in fig. 12, and place the
suctioning unit on the desired side where the
cover was previously removed. Refit the cover
on the unused air out-let hole. Carry out the
installation following the procedure shown
for E200/150 and E200/110 models.
ATTENTION! For versions with V1800 or
V2300 external motors, take great care
when connecting the cable of the motor to
a central unit of the circuit. Extract a con-
nection terminal from the central unit (re-
fer to the attached image).
These motors have two connectors; one is
6-way and the other 2-way. Before con-
necting the 2-way connector, extract a ter-
minal from the central unit, otherwise the
motor will not function correctly.