Care, maintenance and disposal
General
Regular preventive maintenance of the welding torch is essential if trouble-free
operation is to be ensured. The welding torch is subjected to high temperatures
and heavy soiling. The welding torch therefore requires more frequent mainten-
ance than other components in the welding system.
Maintenance at
-
every start-up
-
1
*
-
62
Check wearing parts
-
replace faulty wearing parts
Remove welding spatter from gas nozzle
Check the gas nozzle, spatter guard and insulation for damage and re-
place any damaged components.
Also at every start-up when using water-cooled welding torches:
-
check all coolant connections for tightness (no leaks)
-
check that the coolant can flow unhindered
CAUTION!
Risk of damage from improper hand-
ling of the welding torch.
This can result in severe damage to
property.
Do not strike the welding torch on
hard objects.
Avoid scoring and scratches on the
contact tip.
Do not bend the torch body under
any circumstances.
2