CONNECTION
IMPORTANT: cool the power amplifier properly. To do this, make sure that the place where it is installed has
access to airflow and that the slots in the chassis are free of obstructions.
-
With the amplifier switched off, connect the telephone switchboard to the TEL input. PAGING, connect
all CH and AUX audio sources, and select the LINE/PHANTOM/MIC input type on channels CH 1 to
CH 3 using the channel selectors. For example, if you are connecting a dynamic microphone select the
MIC position, if you are using a preamplified desktop microphone select the LINE position and if it is a
condenser microphone requiring power select PHANTOM.
-
Connect the loudspeakers to the loudspeaker output. Use the 4-8 Ω low impedance output or the 100,
75 or 25 V high impedance line output or the LINE OUT output, depending on the type of loudspeakers
to be connected.
- LOW IMPEDANCE, POWER AMP. OUT 4-8 Ω: you must connect the speakers in a series/parallel
circuit so that the load impedance of the speakers is equal to the impedance of the amplifier and the
power supplied by the amplifier does not exceed the power supported by the speakers.
- HIGH IMPEDANCE, POWER AMP. OUT 100-75-25 V: all loudspeakers must be connected in parallel
and the sum of the power of all loudspeakers must not exceed the power supplied by the amplifier.
- LINE OUT: connect the output to a power amplifier, an active loudspeaker (with amplifier) or a
recording device.
NOTE: do not use multiple types of POWER AMP. OUT at once.
-
Once the connections have been made according to your needs, connect the devices to the power
ZONE 1 (100 V LINE) - 60 W RMS
supply and switch them on. After use, do not forget to switch it off and disconnect it from the mains.
ZONE 1 (100 V LINE) - 60 W RMS
ZONE 2 (100 V LINE) - 60 W RMS
ZONE 2 (100 V LINE) - 60 W RMS
ZONE 3 (100 V LINE) - 60 W RMS
ZONE 3 (100 V LINE) - 60 W RMS
ZONE 4 (100 V LINE) - 60 W RMS
ZONE 4 (100 V LINE) - 60 W RMS
To amplify the power in a given zone, connect the line output of the chosen zone to the input of a power
amplifier. Use the 100 V line output of the power amplifier to connect the loudspeakers as shown in the
following wiring diagram.
ZONE 1
LINE OUT BAL. UNBAL.
G
-
+
COM
4
230 V
115 V
LINE OUT BAL. UNBAL.
ZONE 2
-
+
G
COM
4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ZONE 1
LINE OUT BAL. UNBAL.
CAUTION : SHOCK HAZARD - DO NOT OPEN
G
-
+
COM
RISK OF FIRE-REPLACE FUSE AS MARKED
LINE OUT BAL. UNBAL.
ZONE 3
-
+
G
COM
4
230 V
115 V
LINE OUT BAL. UNBAL.
ZONE 2
-
+
G
COM
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
ZONE 4
LINE OUT BAL. UNBAL.
G
-
+
COM
4
LINE OUT BAL. UNBAL.
ZONE 3
POWER CONSUMPTION: 380 W
-
+
G
COM
~110-120 V AC, 50/60 Hz, FUSE: 6.3 A 250 V
~220-240 V AC. 50/60 Hz, FUSE: 3.15 A 250 V
ZONE 4
LINE OUT BAL. UNBAL.
G
-
+
COM
POWER CONSUMPTION: 380 W
~110-120 V AC, 50/60 Hz, FUSE: 6.3 A 250 V
~220-240 V AC. 50/60 Hz, FUSE: 3.15 A 250 V
100 V LINE
SPEAKER OUTPUT
POWER AMPLIFIER
100 V LINE
SPEAKER OUTPUT
POWER AMPLIFIER
POWER AMP. OUTPUT
ZONE 1
LINE OUT BAL. UNBAL.
G
-
+
COM
4
230 V
115 V
POWER AMP. OUTPUT
LINE OUT BAL. UNBAL.
ZONE 2
-
+
G
COM
4
ZONE 1
LINE OUT BAL. UNBAL.
CAUTION
G
-
+
COM
4
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
POWER AMP. OUTPUT
230 V
115 V
LINE OUT BAL. UNBAL.
ZONE 3
-
+
G
COM
4
LINE OUT BAL. UNBAL.
ZONE 2
-
+
G
COM
4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
POWER AMP. OUTPUT
ZONE 4
LINE OUT BAL. UNBAL.
G
-
+
COM
4
LINE OUT BAL. UNBAL.
ZONE 3
-
+
G
COM
4
POWER CONSUMPTION: 380 W
~110-120 V AC, 50/60 Hz, FUSE: 6.3 A 250 V
~220-240 V AC. 50/60 Hz, FUSE: 3.15 A 250 V
ZONE 4
LINE OUT BAL. UNBAL.
G
-
+
COM
4
POWER CONSUMPTION: 380 W
~110-120 V AC, 50/60 Hz, FUSE: 6.3 A 250 V
~220-240 V AC. 50/60 Hz, FUSE: 3.15 A 250 V
PRIORITY
PRIORITY
MONITOR
MONITOR
PRIORITY
POWER AMP. OUTPUT
LINE OUT
1 W 8
8
25 V
70 V
100 V
POWER AMP. OUTPUT
8
25 V
70 V
100 V
MONITOR
MONITOR
PRIORITY
POWER AMP. OUTPUT
LINE OUT
1 W 8
4
8
25 V
70 V
100 V
POWER AMP. OUTPUT
MAZ-0604
8
25 V
70 V
100 V
MULTI-CHANNEL AMPLIFIER
POWER AMP. OUTPUT
4 x 66 W MAX., 4 x 60 W RMS
4
8
25 V
70 V
100 V
POWER AMP. OUTPUT
8
25 V
70 V
100 V
POWER AMP. OUTPUT
MAZ-0604
4
8
25 V
70 V
100 V
MULTI-CHANNEL AMPLIFIER
4 x 66 W MAX., 4 x 60 W RMS
POWER AMP. OUTPUT
4
8
25 V
70 V
100 V
ZONE 1 (100 V LINE)
MONITOR
MONITOR
PRIORITY
ZONE 1 (100 V LINE)
LINE OUT
1 W 8
8
25 V
70 V
100 V
MONITOR
MONITOR
PRIORITY
POWER AMP. OUTPUT
8
25 V
70 V
100 V
LINE OUT
1 W 8
8
25 V
70 V
100 V
POWER AMP. OUTPUT
MAZ-0604
8
25 V
70 V
100 V
8
25 V
70 V
100 V
MULTI-CHANNEL AMPLIFIER
4 x 66 W MAX., 4 x 60 W RMS
POWER AMP. OUTPUT
8
25 V
70 V
100 V
MAZ-0604
8
25 V
70 V
100 V
MULTI-CHANNEL AMPLIFIER
4 x 66 W MAX., 4 x 60 W RMS
POWER AMP. OUTPUT
8
25 V
70 V
100 V
- 5 -
TELEPHONE
EXCHANGE
TELEPHONE
EXCHANGE
PHANTOM +15 V
TEL PAGING
LINE
MIC
ZONE
T
R
G
VOL
SELECTOR
OFF
ON
1 2 3 4
PHANTOM +15 V
TEL PAGING
LINE
MIC
ZONE
T
R
G
VOL
SELECTOR
TEL. PAGING
CH 1
OFF
PHANTOM +15 V
PHANTOM +15 V
ON
GAIN
GAIN
GAIN
LINE
MIC
LINE
MIC
1 2 3 4
TEL. PAGING
CH 1
PHANTOM +15 V
PHANTOM +15 V
GAIN
GAIN
GAIN
LINE
MIC
LINE
MIC
CH 5
CH 4
CH 3
CH 2
INPUTS
AUDIO PLAYER
CH 5
CH 4
CH 3
CH 2
INPUTS
AUDIO PLAYER
PHANTOM +15 V
TEL PAGING
LINE
MIC
ZONE
T
R
G
SELECTOR
VOL
OFF
ON
1 2 3 4
PHANTOM +15 V
TEL PAGING
LINE
MIC
ZONE
T
R
G
SELECTOR
VOL
OFF
ON
TEL. PAGING
CH 1
PHANTOM +15 V
1 2 3 4
PHANTOM +15 V
GAIN
GAIN
GAIN
LINE
MIC
LINE
MIC
TEL. PAGING
CH 1
PHANTOM +15 V
PHANTOM +15 V
GAIN
GAIN
GAIN
LINE
MIC
LINE
MIC
CH 5
CH 4
CH 3
CH 2
INPUTS
CH 5
CH 4
CH 3
CH 2
INPUTS
EN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN

Publicidad

loading