4
Technical data
4 Technical data
4.1
Electrical data
Voltage supply
PNP, NPN, push-pull
IO-Link
Explosion protection Ex i
a
Current consumption
Idle mode
Switch operation with 2 outputs
IO-Link operation
Protection class
Overvoltage category
Pollution degree
Electrical connection
Connection elements
Connecting cable
Temperature resistance
Electrical safety
Requirements
a
The device labeling indicates a maximum power consumption in switching mode with 2 outputs including self-con-
sumption. The actual power consumption depends on the connected load.
4.2
Inputs
Hysteresis
Repeatability
Switch-on delay
Switching delay
When the sensor is covered
When the sensor is uncovered
Filter time constant
4.3
Outputs
Number
For IO-Link operation
For switching operation
With PNP, NPN, push-pull
Configuration options
Pulse-width modulation (PWM)
Period duration adjustable
Mark-to-space ratio
Switching current
Voltage drop at switching transistor ≤ 1 V
12
DC 24 V SELV
DC 9.6 to 36 V
DC 18 to 32 V
DC 9.6 to 30 V
0.45 W
15 W
0.5 W
3
II
2
M12 plug connector
≥ 90 °C
DIN EN 61010-1:2023
The device must be equipped with an electrical circuit that meets the require-
ments with regard to "Limited-energy circuits".
±1 mm
±1 mm
< 2 s, during this time the switching outputs are blocked
Adjustable 0.3 to 60 s
0.5 s
1 s
Adjustable 0 to 100 s
1 (output signal according to IO-Link communication standard version 1.1)
2 (SIO mode; SIO = standard IO)
2
Hysteresis or window function, switching function, NC contact or NO contact,
output p-switching (PNP) or n-switching (NPN), switch-on and switch-off delay,
pulse-width modulation (PWM), pollution degree detection, wet test with medi-
um
50 to 1000 ms
0 to 100 %
≤ 200 mA per output