Descargar Imprimir esta página

Infiniton PG-QH13 Manual Del Usuario página 31

Estufa de gas

Publicidad

Idiomas disponibles

Idiomas disponibles

How to use
Switching on the heater
1.
Turn the control knob to the "OFF" position (Figure a).
2. Open the gas cylinder valve fully. Note: For initial start-up or after any cylinder change, hold the con-
trol knob in for 10 seconds to purge air from the gas lines before proceeding. Push in the gas control
knob and turn it counterclockwise to "IGNITER" (Figure b) to light the fire.
3. If necessary, continue to press and turn the control knob counterclockwise until the heater ignites (a
clicking sound should be heard).
4. Once the fire is lit, release the control knob. Press and turn the control knob to the "HIGH" position,
then release the control knob. If a lower temperature is desired, press the control knob and turn it
clockwise to the "LOW" position (Figure c).
Notes:
If the burner does not stay lit, all valves must be closed and a waiting period of at least 5 minutes must
elapse before attempting to light the burner.
Switching off the heater
1.
To turn the burner off, press the control knob and turn it clockwise to the OFF position.
2. Turn the cylinder valve clockwise to the OFF position and disconnect the regulator when the burner is
not in use.
Storage
1.
Always close the gas valve on the cylinder after use or if there are any problems.
2. Remove the pressure regulator and hose.
3. Check the gas valve for looseness or damage; if you think it is damaged, ask your gas supplier to
replace it.
4. Never store the gas cylinder in places without adequate ventilation.
OFF
Heater stops working
HI
Maximum temperature position
LO
Minimum temperature position
If this heater model has glass panes, check
that there are no cracks in the panes before
lighting the heater.
30
English
infiniton.es

Publicidad

loading

Este manual también es adecuado para:

8445639003114