Installation
Heater position and levelling
•
This heater is primarily intended for outdoor use. Always ensure
that there is adequate ventilation of fresh air.
•
Always keep an adequate distance to combustible elements, i.e.
100 cm at the top and at least 100 cm at the sides.
•
The heater must be placed on a firm, level floor.
•
Never use the heater in a potentially explosive atmosphere,
which may contain petrol or other flammable liquids or vapours.
Gas requirements
•
Use only propane, butane or any of their mixtures.
•
The pressure regulator and hose assembly used must meet local code standards.
•
Installation must conform to local codes or, in the absence of local codes, to the standard for storage
and handling of liquefied petroleum gases.
•
A dented, rusted or damaged cylinder can be dangerous and should be checked by your cylinder
dealer.
•
Never use a cylinder with a damaged valve.
•
Never use a cylinder with a damaged valve connection.
•
The cylinder must be prepared to allow the extraction of vapours from the cylinder.
•
Never connect an unregulated cylinder.
Leak test
The gas connections of the heater are tested for tightness at the factory before shipment. A comple-
te gas tightness check must be carried out at the installation site due to possible mishandling during
transport or excessive pressure applied to the gas.
applied to it.
•
Prepare a soap solution with one part liquid detergent and one part water. The soap solution can be
applied with a spray bottle, brush or cloth. In case of leakage, soap bubbles will appear.
•
Check the operation of the heater with a full drum.
•
Make sure that the safety control valve is in the OFF position.
•
Turn on the gas supply.
•
In case of leakage, turn off the gas supply. Tighten any leaking connectors, turn on the gas supply
and retest.
•
Never leak test while smoking.
21
English
Ceiling
100 cm