Descargar Imprimir esta página

Atlas Copco ErgoPulse 14PTS250 HR20-RE Instrucciones De Empleo página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
EP 14PTS-HR20
Fig. 12 To fill the pulse unit with oil
Operation No. 1 – 10 (after disassembly of pulse unit)
Due to a possible microleagage of oil from the pulse unit, it could
be necessary for refill the unit between the regular overhaul
intervals.
The frequency of this procedure depends on the type of
application, number of cycles, tightening time etc. A indication of
too little oil is decreased torque and increased pulse frequency.
After disassembly of pulse unit, fill with oil according to operation
No. 1 – 3 below. Run the machine in a vice for 10 seconds
according to operation No. 4. Then continue according to
operation No. 5 – 10.
Oil : 22 cSt / 40 ˚C (ISO VG22)
1
To refill the pulse unit
Operation No. 5 – 10
Keep the pulse unit at normal room temperature.
Note Before the refill : Let the bubbles in the oil fade away.
Check that there are no bubbles in the oil and that the pulse unit is
completely full (100 %) before reducing the oil volume according
to operation No. 9.
Temp : ca. 20 o C
5
2
Fill full
No. : 4080 0841 80
6
7
Atlas Copco Tools - No. 9836 1621 00
For best performance use Atlas Copco Hydraulic Oil for ErgoPulse:
The Oil Filling Kit is composed of Atlas Copco Hydraulic Oil for
ErgoPulse (50ml) and a syringe (1 ml). Ordering No. : 4081 0121 90
Also hydraulic oil, 22 cST / 40°C (ISO VG22), can be used.
4 Nm
3 mm
3
Correct oil quantity : Fill to 100%, then reduce according to table.
After the refill – Check the tightening torque.
Model
EP 14PTS HR20 – RE
8
1 ml
Fill to
100 %
Technical Instructions
6 – 7 Bar
4
Ca 10 Sec.
Oil volume to
Approx. oil volume
be reduced fom 100%
in pulse-unit
2.3 ± 0.05 ml
Reduce
according to table
9
29 ml
4 Nm
3 mm
10
27

Publicidad

loading