Technical Instructions
Fig. 13 Position of stop pin
The "X" measurement is correctly set at our factory before delivery.
Normaly the "X" measurement has to be adjusted only after that the
parts concerned have been dismantled.
If the accuracy is not as good as expected, check the position of the
stop pin (Ref.No. 157). The position of the stop pin is adjusted by
turning the screw (see fig. beside).
The measurement "X" is hard to measure. It is possible to get the
position by starting from "X" = zero.
Hold the pulse unit vertically and check that the stop pin is covering a
part of the centre hole (i.e. "X" is more than zero). Arrange the shut
off valve in the centre hole, see fig. beside. Adjust the screw until the
valve drops down in the hole of the stop pin. In this position "X" is
zero.
Place a gauge (i.e. a drill bit) with a diameter "D" according to table
below in the hole. Then unscrew the screw till the gauge is just tight in
the hole. Note : the gauge must not be squeezed by the stop pin.
An another way to get an appropriate "X" measurement is to unscrew
the screw from the position "X" = zero. Unscrew the No. of turns given
in the table below. The measurements given in the table will give a
basic adjustment. Check the diameter "D" with a drill bit or similar.
An increased "X" means a higher tightening torque and a decreased
"X" means a lower tightening torque. It is possible to fine-adjust the
tightening torque by turning the screw. Change with a 1/8 of a turn at
a time.
Model
"D"
EP 14PTS
1.55 mm
Fig. 14 Service instructions
Dismantling of ball bearings
28
No. of turns to
"X"
unscrew to get "X"
1.5 mm
1.5
4080 0536 00
Atlas Copco Tools - No. 9836 1621 00
"X" = 1.7 mm
4080 0206 07
EP 14PTS-HR20
Pitch of thread = 1.0 mm/rev.
"X" = +
"X" = –
Hex. 3.0 mm
"D" = 1.35 mm
Ref. No. 157
"X"
4080 0208 03
"D"