Descargar Imprimir esta página

L.B.White Premier 350 DF Manual Del Usuario E Instrucciones página 14

Calefactores canalizados de doble combustible
Ocultar thumbs Ver también para Premier 350 DF:

Publicidad

Idiomas disponibles

Idiomas disponibles

14
Premier Ductable Heaters
Start-Up Instructions
For normal start-up:
Connect an approved electrical cord to the male
power receptacle.
A. Heating Mode Operation:
a. Open all manual fuel supply valves. Check for
gas leaks using an approved leak detector.
b. Position the selector switch to heat. See Fig. 11.
FIG. 11
c. The fan motor will start, the igniter will spark and
ignition will occur.
d. If a thermostat is used, it will cycle the heater on
and off based on the temperature set point.
ATTENTION
■ It is normal for air to be trapped in the gas hose
on new installations. The heater may attempt
more than one trial for ignition before air is finally
purged from the line and ignition takes place.
When the switch is set to heat, three status lights
(see Fig.12) will be activated in sequence as specific
circuits are checked by the ignition control. If the
heater does not light, and a status light is off, refer
to the troubleshooting guide or the QR code in this
manual.
Owner's Manual • Premier 350 2.0
FIG. 12
B. Ventilation Mode Operation
When the selector switch is positioned to vent, none
of the status lights will be on. The fan motor will start,
but the igniter will not spark, nor will ignition occur. This
feature is used only when air circulation is required.
The heater will not cycle on its thermostat setting. To
discontinue the ventilation feature, position the switch
to off or heat.
C. Off O
• Position the switch to midpoint. O
Gas Control Valve
• The gas control is a single stage design valve. When
24 VAC is applied to the valve, it will opens and
delivers full gas output.
• The gas control valve has a manual shut off feature
incorporated into the valve assembly. Ensure the
indicator is turned to the ON position. See Fig. 13.
.FIG. 13

Publicidad

loading

Este manual también es adecuado para:

Cs350 2.0