Descargar Imprimir esta página

Erreka ARES Manual Del Instalador página 25

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
VERY IMPORTANT:
T C
T h e
c l o s i n g
stopper and the TA
opening stoppers
must be installed in
all cases. Failure to
do so may damage
the operator due to
stresses beyond its
design limits.
INSTALLATION COMPONENTS:
1
Operator
2
Flashing light
3
Exterior photocells
4
Key switch
5
Wall pushbutton
6
Switchboard
7
Connections box
8
Interior photocells
9
Electrolock
10 Stop on closing
11 Antenna
Junction boxes (7) are recommended for the connections between
the operator, the control panel and the other components. The
cables must enter and exit at the bottom.
ELECTRICAL CABLING:
Element
A: Main power supply
B: Flashing light
C: Photocells (Tx / Rx)
D: Pushbutton or key switch
E: Operator (125/230 VAC)
F: Antenna
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
E1
Nº wires x section
2
3x1.5mm
2
2x0.5mm
2
2
2x0.5mm
/ 4x0.5mm
2
2x0.5mm
2
4x1mm
Coaxial cable 50k (RG-58/U)
E1 E2
E2
We recommend using the
VIVO-M201(M)
M101(M) switchboard.
Maximum length
30m
20m
30m
25m
20m
5m
For greater safety, Erreka recommends installing the
photocells (3) and (8).
E1: left model
(BGR_I)
E2: right model
(BGR_D)
E68A
or
VIVO-
ARES electro-mechanical operator
English
21

Publicidad

loading