INSTALLATION
6
ELECTRICAL CONNECTIONS
The ARES operators, along with the recommended
switchboards, allow the implementation of a
slowdown system, with the speed slowing down at
the end of the closing and opening operations.
VIVO-M201(M)
A1, A2
Operators
C1, C2
Capacitors (230V-8μF / 110V-25μF)
DL4
Gate opening
DL5:
Gate closing
PUL1
Close mini-pushbutton
PUL2
Open mini-pushbutton
T
Earth connection
Turning direction:
• When pressing PUL1 (close), DL5 lights up and the A1 G2-G3 and A2 G5-G6 cable connectors are activated.
• When pressing PUL2 (open), DL4 lights up and the A1 G1-G3 and A2 G4-G6 cable connectors are activated.
If the turning direction is not correct, interchange the cables connected in cable connectors G1-G2 or G4-G5.
7
FINAL CHECKS
Checking the closing power
The installation must respect the values
indicated in Standard EN 12453:2000. All
measurements must be made in line with the
method described in Standard EN 12445:2000.
• F
< 400N in spaces between 50mm and
d
500mm
• F
< 1400N in spaces> 500mm
d
28
Installation Manual
A2 operator connections:
G4 Open
G5 Close
G6 Common (COM), grey cable
We
recommend
using
switchboard (for single operator installations) and
VIVO-M201(M) (for twin operator installations).
A1 operator connections:
G1 Open
G2 Close
G3 Common (COM), grey cable
User instruction
1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the use manual.
2 Signal the gate, showing that it opens automatically
and indicating how to operate it manually. Where
appropriate, indicate that operation is using the
remote control.