FAILURE DIAGNOSIS
Problem
The operator does not make
any movement when the
opening or closing controls
are activated
When activating the opening
or
closing
controls,
operator is activated but the
gate does not move
The door opens but does not
close
The gate moves in an irregular
manner
The door cannot completely
open and/or close
30
Installation Manual
Cause
Absence of system power supply
voltage
Electrical installation defective
Control panel or control devices
defective
Motor / winding damaged
Motor capacitor defective
Gate obstructed or blocked
the
The operator has been installed
without respecting the installation
levels
Photocells or safety devices poorly
c o n n e c t e d ,
d e f e c t i v e
permanently activated
Command devices permanently
activated
G a t e p a r t i a l l y o b s t r u c t e d o r
blocked
The operator has been installed
without respecting the installation
levels
The photocell detects an obstacle
The resistance of the gate has
increased when opening and/or
closing
Operator force during opening
and/or closing is too low
The operator has been installed
without respecting the installation
levels
Motor capacitor defective
Motor / winding damaged
Solution
Check the fuses
Re-establish the power supply
Check that the installation does not
present any short-circuits or cut-off
points
Check these elements, seeing their
respective manuals
C h e c k t h e m o t o r a s d e s c r i b e d i n
"Checking the operators" on page 31
Test operation using a new capacitor
Unblock, adjust and lubricate the gate
articulations
C a r r y o u t t h e i n s t a l l a t i o n a g a i n ,
respecting the levels indicated in the
"Assembly positions and levels" on
page 26
C h e c k t h e c o n d i t i o n o f t h e s e
o r
components
A command device permanently gives an
o p e n i n g c o m m a n d . C h e c k t h e
command devices
Unblock, adjust and lubricate the gate
articulations
Reinstall in line with the levels shown in
the "Assembly positions and levels" on
page 26
Remove the obstacle and try again
Check the moving parts of the gate and
remove the resistance
Use the control panel programming to
increase the opening and/or closing
force
C a r r y o u t t h e i n s t a l l a t i o n a g a i n ,
respecting the levels indicated in the
"Assembly positions and levels" on
page 26
Test operation using a new capacitor
C h e c k t h e m o t o r a s d e s c r i b e d i n
"Checking the operators" on page 31