Descargar Imprimir esta página

Erreka ARES Manual Del Instalador página 31

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Levelling
The supports should be positioned so as the operator forms an angle of 1° with regards
to the horizontal, remaining lower on the gate support side.
Mount the wall support
Respect the levels indicated in "Assembly
1 1
positions and levels" on page 26.
The screws (1) and plugs (2) are not
supplied. Use screws and plugs which are
suitable for the place of attachment and the
weight and effort of the operator.
Position the gate support
Extend the stem as far as it will go and then screw
it in 1 full turn (360º). Then attach the gate bracket.
Respect the levels indicated in "Assembly
positions and levels" on page 26 and the slant
of the operator (see "Levelling" on page 27).
The screws (5) are not supplied. Use screws
which are suitable for the place of
attachment and the effort required.
Mount the operator on the wall support
Mount the operator on the gate support
360º
Introduce the shaft (3) and secure with the cap
(4), using a 6 mm Allen key.
It is mandatory to place the T-cap.
Introduce the shaft (6) and secure with the cap
(7), using a 6 mm allen key.
1 1
ARES electro-mechanical operator
INSTALLATION
27

Publicidad