MAINTENANCE AND DIAGNOSIS OF FAILURES
B- Checking the windings with a multimeter
G1
G2
COM
For accurate readings, disconnect the operator from
the control panel and remove the capacitor between
G1 and G2.
3
SCRAP
The operator, up until the end of its useful life,
must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner we will avoid possible accidents and
damage to adjacent facilities.
4
SPARE PARTS
If the operator needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
32
Installation Manual
R1
G1
Ω
G2
COM
R2 y R1
R2
Ω
Check the following:
• Using a multimeter, check that electrical resistance
between cables G1-COM (R1) and G2-COM (R2) is
similar.
• Also check that the resistance between G1-G2 (RT)
is approximately the sum of between G1-COM (R1)
and G2-COM (R2).
The operator must be deposited in the
appropriate containers for subsequent
recycling, separating and classifying the
different materials in line with their
nature. NEVER deposit it in domestic
rubbish or in landfills which are not controlled, as
this will cause environmental damage.
Use only original spare parts.
RT y R1 + R2
RT
G1
Ω
G2
COM
S68B