Setting The Temperature Parameters - FAS FASTER GCD Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

22
Command 25 Enable change unit motor and coin input micro (if present):
Step one: the system asks if you want to enable the motor that acts on the change unit. Value 1 = enabled;
Value 0 = not enabled. Default value = 0.
Step two: the system asks if you want to enable the presence of the microswitch that acts on the coin input.
Value 1 = enabled; Value 0 = not enabled. Default value = 0.
Step three: the system asks if you want to set a change unit motor cycle at time intervals expressed in
minutes during the periods of inactivity of the vending machine. The single cycle is programmable between a
minimum time of 2 min up to a maximum of 250 min. Default value = 0 = cycle not enabled.
Command 26 Child-proof system activation: This command allows you, by means of an electrical contact,
to manage a childproof device when it is fitted on the machine. Step one: enabling control of the childproof
device is requested. Value 1 = enabled; value 0 = not enabled. Step two: the system asks which selections
must be subject to sales restrictions.
ELECTRICAL CONNECTION OF THE CHILDPROOF DEVICE: The connection must be made between a
normally-open contact of the childproof device and the 2 pins of connector JP2 connector on the main board,
E
shown in the figure.
N
G
L
I
S
H
Use connector type Molex micro-fit 3.0 part no. 43025-1600 for the connection.
9.1.2

SETTING THE TEMPERATURE PARAMETERS

Command 40 Enable heated glazing and selection of the fridge unit on SLAVE :
This command allows you to set the model of the refrigeration unit with or without defrost solenoid.
Then, you will be have the option to enable (value set to 1) heating the double-glazing if the glass has an
incorporated resistance, or disable this device (value set at 0). If the command is set at 1 it will be possible to
manage the time bands for turning the demister resistance on and off during the day.
Furthermore, if a slave is enabled (see Command 49), this command lets you set the model of the
connected slave.
If FAST SLAVE = 0
If FASTER SLAVE = 1
If the value is set at = 0 (FAST SLAVE), the values of Command 41 (internal temperature setting) are the
following: predefined +8°C, and can vary between +6 to
disabled.
Whereas if the value is set at = 1 (FASTER SLAVE), the same parameters apply as those for commands 41
to 48 of this manual.
Command 41 Sets cabinet temperature:
This command sets the lower internal cabinet temperature of the machine, i.e. the temperature below which
the compressor is turned off. The preset value is +3°C. This value can be varied between +2 to +25°C.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
Main board
The command setting MUST BE consistent with the machine model otherwise the machine
will not function correctly.
FASTER GCD – Issue 03
Detail of connector JP2
+25°C. Commands 45, 46 and 48 are also