Connecting the filter module ProfiClear Premium L
Ensure that the ProfiClear Premium Fleece filter is 200 mm higher than the downstream filter module
so that the connections of the two modules (outlets and inlets) are at the same height.
Use 24 commercially available concrete slabs of 500 × 500 × 50 mm each. Form a base of
1500 × 1000 mm and construct four layers above each other.
Preparing the outlets
To connect a ProfiClear Premium module filter L, you require the OASE connection set, art. no. 92768.
Close the outlets DN110 with the closing caps.
Remove the sealing plugs on both 150 mm outlets and install the 150 mm outlet branch instead.
– To reach the internal screws, it is necessary to remove the ClearWave filter element.
(→ ClearWaveRemoving and cleaning filter elements)
54