Descargar Imprimir esta página

Oase ProfiClear Premium Fleece Serie Instrucciones De Uso página 58

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 148
Commissioning/start-up
WARNING
Risk of severe injuries or death by electric shock.
Disconnect all electrical devices in the water from the power supply before reaching into the wa-
ter.
Disconnect the unit from the mains before you start working on it.
NOTE
The unit will be destroyed if it is operated with a dimmer or timer. It contains sensitive electrical com-
ponents.
Do not connect the unit to a dimmable power supply.
Do not connect the unit to a timer.
Prior to initial commissioning
Thoroughly clean the pond before starting up the filter system for the first time to ensure that the
filter system is not overloaded by excessively soiled water. OASE recommends using the pond vac-
uum cleaner PondoVac for cleaning the pond.
 This cleaning measure is normally not necessary for newly installed ponds.
Order of starting up steps
How to proceed:
1. Close the slide valve of the dirt outlet DN 75.
2. Switch on the filter pump and, if necessary, the UVC clarifier.
3. Switch on the control system and set the required parameters. (→ Operation)
– Ensure that the water is returned to the pond via the return pipe.
4. Check all pipes, hoses and their connections for leaks.
– Expansion seals may leak initially until they have fully expanded on contact with water.
5. If you are using a new filter, put filter starter into the container if necessary.
– For safety reasons, the drive is stopped while the container cover is lifted. The display of the
control system shows Er11.
It takes approx. 1 to 2 months before the micro-organisms in new filters are fully established.
During this time – or at a water temperature of <10 °C – biological cleaning may be limited.
– When using filter starters, medicines or pond water treatments, leave the UVC pre-clarifier
switched off for at least 36 hours so as not to impair their efficacy.
During the pond season, it is necessary for the filtration system to run 24 hours a day.
58

Publicidad

loading