Self-diagnosis display
The camcorder has a self-diagnosis display.
LCD screen
This function displays the camcorder's condition
with five digits (a combination of a letter and
figures) on the LCD screen. If this occurs, check
the following code chart. The five-digit display
informs you of the camcorder's current
condition. The last two digits (indicated by □□)
will differ depending on the state of the
camcorder.
Self-diagnosis display
• canon
You can service the camcorder
yourself.
•E:OD:DD
Contact your Sony dealer or local
authorized Sony facility.
STBY
\i i ll i M
-"C : 21: 00c
^dmin1
40min Si
Five-digit display
Cause and/or corrective actions
C:21:DO
• Moisture condensation has occurred.
-» Remove the cassette and leave the camcorder for at least 1 hour.
(p. 83)
022:00
• The video heads are dirty.
-> clean the heads using the Sony DVM12CL cleaning cassette (not
supplied), (p. 84)
023:00
• You are using a battery pack that is not an "InfoLITHIUM" battery
pack.
-> Use an "InfoLITHIUM" battery pack. (p. 7)
031:00
032:00
• A servicable situation not malfunctioned above has occurred.
4 Remove the cassette and insert it again, then operate the
camcorder, (p. 11)
-» Disconnect the power cord of the AC power adaptor or remove
-
-
the battery pack. After reconnecting the power source, operate
the camcorder.
E:61:DO
E:62:DO
• A camcorder malfunction which you cannot service has occurred.
Contact your Sony dealer or local authorized Sony service
facility and inform them of the five digits, (example: E:61:10)
If you are unable to resolve the problem, contact your Sony dealer or local authorized Sony service