7. Operation
7.1 Carrying and using the system
The scanner can be used without the monitor for scan-
ning, or the monitor can be carried in the PSA 61 soft
pouch on the PSA 60 shoulder belt. The first option is
advantageous when working in areas that are difficult
to access and maximum mobility is required, such as
on a scaffold or ladder. When the scanner memory is
full (9 Imagescans made, 1 complete Blockscan or 30 m
of Quickscan have been recorded), the user must return
to the monitor to transfer the data. The monitor can be
kept nearby (e.g. at the foot of the scaffold, in a vehicle,
in the site office etc.). When the user intends to make
more scans than the scanner is capable of storing in its
memory and wishes to avoid repeated journeys to the
monitor, the monitor can be attached to a belt or carried
using the shoulder strap supplied.
-CAUTION-
The temperature inside a vehicle that is left exposed to
the heat of the sun can easily exceed the maximum stor-
age temperature for the PS 200. Damage to one or more
components of the PS 200 may occur if it is stored in
temperatures exceeding 60 °C or 158 °F.
7.2 Operating the scanner
7.2.1 Control panel and screen layout
1
2
1 – Arrow buttons
Toggle up or down in options or
values.
Confirms a value or a selection.
2 – Confirm button
3 – On/off button
4 – Cancel button
Cancels an input or moves back
one screen.
5 – Record button
Starts or stops a recording.
2
1
3
1 – Menu area. Functions that can be selected using the
Arrow and Confirm buttons
2 – Status information – information such as battery
level, memory status
Printed: 07.07.2013 | Doc-Nr: PUB / 5070389 / 000 / 00
3
4
5
3 – Variable area – information displayed is user feed-
back – e.g. measuring mode, bar depth, scan progress
etc.
7.2.2 Switching on and off
To switch the scanner on or off, press and hold the On/off
button momentarily.
The scanner can be switched off only when it is in the
main menu.
7.2.3 Main menu
The system always starts in the main menu. All scanning
functions and set-up options are selected here. The bat-
tery charge status is displayed at the top of the screen
together with the memory status. The various scan modes
and settings menus are displayed as icons on the left
side of screen. Use the Arrow buttons to toggle between
these options. The Confirm button selects the option.
Quickscan – The remaining memory for Quickscan
recording is shown at the top of the screen in meters or
feet (depending on the scanner type and units set).
Imagescan – The number of Imagescans in the scanner,
up to a maximum of 9, is shown at the top of the screen.
Blockscan – The number of Imagescans in the scanner,
up to a maximum of 9, is shown at the top of the screen.
en
45