5.3.1 Electromagnetic compatibility
Although the appliance fulfills the requirements of the
relevant regulations, Hilti cannot rule out the possibili-
ty that:
Other equipment (e.g. airborne navigation systems,
●
medical equipment) will be disturbed by the PS 200
or
That this disturbance will lead to a malfunction of the
●
PS 200. In such cases or in case of any uncertainty,
control measurements must be carried out.
5.4 General safety measures
5.4.1 Mechanical
Check the appliance for possible faults before use.
●
In case of a fault, have the appliance repaired by Hilti
Service.
If the appliance is dropped or subjected to an impact,
●
its accuracy must be subsequently checked.
Check the accuracy of the appliance each time before
●
use.
When moving the appliance between temperature
●
extremes, allow it to become acclimatize to the new
temperature before use.
Even though the appliance is protected against the
●
ingress of moisture, always wipe it dry before storing
it in the toolbox.
5.4.2 Electrical
Avoid shorting the battery terminals. Such electrical
●
shorting can cause fire.
Ensure that the exterior surfaces of the battery are
●
clean and dry before connecting it to the charger.
Use only the battery specified in these operating
●
instructions.
Ensure that the battery is safely disposed of at the end
●
of its life.
When transporting the appliance or storing it for a
●
longer period of time, remove the battery. Before
reusing it, inspect the battery for any signs of leak-
age or damage.
To avoid environmental pollution, the battery must be
●
disposed of in accordance with country-specific reg-
ulations. In case of doubt, contact Hilti.
Printed: 07.07.2013 | Doc-Nr: PUB / 5070389 / 000 / 00
5.4.3 Liquids
-WARNING-
A corrosive liquid can leak from defective batteries.
Avoid contact with this liquid. Should the liquid come
into contact with the skin, wash the area affected liber-
ally with soap and water. In case of contact with the
eyes, rinse them immediately with water and consult a
doctor.
5.5 Requirements to be met by the user
The appliance is intended for professional users.
●
The appliance may be used, maintained and cared for
●
only by authorized, personnel who have recieved
instruction in its use. This personnel must be specially
instructed in the hazards associated with the appli-
ance.
Always concentrate on your work. Always think care-
●
fully about what you are doing. Do not use the appli-
ance if you are unable to concentrate.
Do not use the appliance if it appears to be defective
●
in any way.
If you are unsure of any scan results, consult a Hilti
●
specialist before proceeding.
Observe all warning and information messages dis-
●
played by the scanner and monitor.
5.6 Scanning requirements and limitations
Always check the accuracy of the appliance before
●
commencing work on structures where measurements
have safety and structural stability implications. Scan
a reinforcing bar of known location, depth and diam-
eter and check the results against the accuracy spe-
cifications.
Do not use the PS 200 S scanner if the wheels do not
●
turn freely or appear to be worn. Contact Hilti for repair
information. Additionally, you can clean or replace the
wheels – refer to section 8.
Check the settings made in the appliance before use.
●
Apply only light pressure to the scanner when mov-
●
ing it across the surface.
Reinforcement that lies beneath the uppermost layer
●
of reinforcement may not be detected.
Remove all items such as rings, bracelets, etc. before
●
commencing scanning.
en