Descargar Imprimir esta página

Ecolab EcoPro Instrucciones De Servicio página 157

Ocultar thumbs Ver también para EcoPro:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Display
Fault
No feedback from gear
box when switching on
If the fault is still present after all checks have been completed, please send
the pump to the Customer Service team.
Ecolab Engineering GmbH' on page 9
Resetting error messages
1.
[Press the ON/OFF] button
ð Both LEDs light up green briefly.
Malfunctions and troubleshooting
Effect
Cause
Contact problem with
feedback cable
Pump is stopped
Feedback PCB faulty
Ä Chapter 1.5 'Repairs/returns to
for approx. 1 second.
55
Action
Check the feedback
cable connection
Replace the feedback
PCB
MAN046879 Rev. 12-12.2023