Technical data
General data
Name
Max. metering output [l/h]
Min. metering capacity [l/h]
Max. metering counterpressure [MPa (bar)]
Max. stroke frequency [1/min]
Metering volume / stroke [ml] 50 Hz/60 Hz
Reproduction accuracy [%]
Max. conveyable viscosity
[mPas] with valves
Permissible ambient
temperature [°C]
Max. suction height [mWs]
Max. suction length [m]
Max. suction side pre-pressure [MPa (bar)]
Min. differential pressure Suction/pressure side [MPa
(bar)]
Min. hose Ø [mm] at viscosity
Noise level [DBA] at 1 m distance
(in accordance with DIN EN 12639/ EN ISO 9614-2)
Weight [kg]
Licences
1)
Values calculated using water as a metering medium at a temperature of
20°C.
2)
Values vary depending on calibration.
3)
Measurement in the MK240 heating cabinet.
4)
Suction heights determined with clean, wet valves at maximum stroke
frequency.
5)
Value in brackets applies to suction/pressure models with PTFE seals.
Metering mode
Viscosity low
1)
Metering mode
Viscosity high
Metering mode
Viscosity low
2)
Metering mode
Viscosity high
2)
Standard
Spring-loaded in
metering mode
"Viscosity low"
Spring-loaded in
metering mode
"Viscosity high"
3)
1, 4)
1)
Up to 50 mPas
Over 50 mPas
Model
Model
00510X
01110S
5
11
3,3
7,3
0,05
0,11
1 (10)
171
160
114
107
0,53
1,04
100
500
1000
2 - 45
0,2 (2)
0,1 (1)
5
6
6
9
3,1
CE, UKCA, UL
81
Technical data
Model
Model
Model
03003S
05010M
12003M
30
50
120
20
33,3
80
0,30
0,50
1,2
0,3 (3)
1 (10)
0,3 (3)
162
164
108
109
3,16
5,74
13,51
< ± 3
100
200
100
250
500
250
500
1000
500
5)
2 (1,5)
3
0,1 (1)
0,2 (2)
0,1 (1)
0,05 (0,5)
0,1 (1)
0,05 (0,5)
9
12
12
19
< 60
3,8
5,2