Descargar Imprimir esta página

PRESIDENT MC KINLEY II FCC Manual Del Usuario página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

3.
Turn the rotary CH knob (6) or use the UP/DN buttons (6) on the
microphone to select the microphone type,
(electret).
4a. Short press the CH knob (6) again to validate your choice and
stay in the MENU.
4b. Long press (1s) the CH knob (6) again to validate your choice
and exit the MENU.
disappears from the display.
5.
If no key is pressed, the unit exits MENU after 10 seconds.
appears from the display.
Original 6 pins PRESIDENT microphone is electret type.
7) SWR
(in CB mode only)
Press the CH knob (6) for 4 seconds to enter MENU.
1.
Turn the rotary CH knob (6) or use the UP/DN buttons (6) on the
microphone to select the menu {SWR}.
2.
Press the CH knob (6) to confirm. The Message shows the active
channel and SWR, for example {CH 40 SWR}.
-
The radio goes to
TX
mode automatically without pressing PTT key
(13) and starts SWR measurement. Measurement time is 5 minutes
maximum. The remaining time is displayed on sub Indicator.
-
Adjust your antenna.
-
Tone beep* is continuous when SWR value is equal to1. 0 . The
space between two beeps becomes longer when SWR value
moves away from1. 0 .
Volume Beep is adjustable with VOL knob (1).
-
Display shows the SWR value. For example 2. 5 .
-
3.
Short press the CH knob (6) again or then PTT switch (13) to validate
your choice and exit the MENU.
*Please check that the beep volume is set to a comfortable
listening level.
See the § ADJUSTMENT OF SWR on page 6.
8) TONE
TONE function allows adjusting the
+5.
(dynamic) or
dis-
appears.
disappears from the display.
RX
tone, 11 steps from -5 to
Press the CH knob (6) for 4 seconds to enter MENU.
1.
Turn the rotary CH knob (6) or use the UP/DN buttons (6) on the
microphone to select the menu {TONE}.
2.
Press the CH knob (6) to confirm. The current value blinks in the
display.
3.
Turn the rotary CH knob (6) or use the UP/DN buttons (6) on the
microphone to change the value.
4a. Short press the CH knob (6) again to validate your choice and
stay in the MENU.
4b. Long press (1s) the CH knob (6) again to validate your choice
and exit the MENU.
5.
If no key is pressed, the unit exits MENU after 10 seconds.
appears from the display.
Default value is 0.
9) EMG SET 1
Allows to determine the emergency channel 1.
Press the CH knob (6) for 4 seconds to enter MENU.
1.
Turn the rotary CH knob (6) or use the UP/DN buttons (6) on the
microphone to select the menu {EMG 1}. "EMG" blinks.
2.
Press the CH knob (6) to confirm, the modulation mode, blinks in
the display.
3.
Turn the rotary CH knob (6) to set the modulation mode: AM, FM,
LSB or USB.
4.
Press CH knob (6) to confirm the modulation mode. The second
parameter, the channel, blinks in the display.
5.
Use the rotary CH knob (6) to select the channel.
6a. Short press the CH knob (6) again to validate your choice and
stay in the MENU.
6b. Long press (1s) the CH knob (6) again to validate your choice
and exit the MENU.
7.
If no key is pressed, the unit exits MENU after 10 seconds.
appears from the display.
See the § EMG on page 10.
Emergency channel 1 default is 9 AM.
14
disappears from the display.
disappears from the display.
appears.
dis-
appears.
dis-

Publicidad

loading