INSTALLATION
INSTRUCTIONS
17
Venfing
fhe
dryer
(conf.)
Ductwork
Recommended
(10.2 cm)
(10.2 cm)
UseOnly for Short
Run Installations
(6.35 cm)
0
I
2
3
4
0
I
2
3
4
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (14.3 m )
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
Y
-@ NOTE
Deduct 6 fL (1.8 m) for each additional
elbow. It is not recommended
|
to use more than four 90 ° elbows.
.]
ROUTING AND CONNECTINGDUCTWORK
@NOTE
-,
Follow the guidelines
below to maximize
drying
performance
and
reduce lint buildup
and condensation
in the ductwork.
Ductwork
and fittings
are NOT included
and must be purchased
separately.
• Use 4-inch (10.2 cm) diameter
rigid or semirigid
metal ductwork.
• The exhaust duct run should be as short as possible.
• Use as few elbow joints as possible.
• The male end of each section
of exhaust duct must point away from
the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork
that runs through
unheated
areas in order to
reduce condensation
and lint buildup
on duct surfaces.
• Failure to exhaust the dryer correctly
will void the dryer's warranty.
CORRECT VENTING
INCORRECTVENTING