INSTALLATION
INSTRUCTIONS
27
Insfallafion
fesf
(Exhausf
check)
(conf.)
, Check the Error Code before you call for service
Err0r code
tE
HS
PS, PFor nP
Temperature sensor failure
. Turn off the dryer and call for
service.
Humidity
Sensor
failure.
. Turn off the dryer
and call for
service.
Electric dryer power cord is not
connected
correctly, or house power
supply is incorrect.
House fuse is blown, circuit breaker has
tripped, or power outage
has occurred.
Check the power supply or the
connection of power cord to the
terminal block. Refer to the Connecting
Electric Dryers section of this manual
for complete instructions.
Reset circuit breaker or replace fuse.
Do not increase the fuse capacity.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.
• Check the duct condition
If the test displays FLOW SENSE, check the exhaust
system for
restrictions
and damage.
Repair or replace the exhaust system as
needed.
@ NOTE
When the dryer is first installed,
this test should
be performed
to
alert you to any existing
problems
with the exhaust
duct in your
home. However,
since the test performed
during
normal
operation
provides
more accurate information
on the condition
of the exhaust
duct than does the installation
test, FLOW SENSE
displayed
during
the two tests may not be the same.
Do not interrupt
the test cycle, as this could result in the wrong
results.
Even if FLOW SENSE is not displayed
during
the test cycle, some
restrictions
may still be present in the exhaust
system. Refer to
the Venting
the Dryer section of this manual for complete
exhaust
system and venting
requirements.
J
Restricted
or Blocked
Airflow
/
I
I
Avoid
long runs or runs with
multiple
elbows or
bends.
Excess or crushed
transition
duct
Too many elbows or
exhaust
too long
Check for blockages
and lint buildup.
Make sure the ductwork
Js not crushed
or restrJcted.
Crushed or
damaged
exhaust