Only. use. original. SIME. accessories.
and.make.sure.that.connections.are.
correct. as. indicated. in. the. instruc-
tions.supplied.with.the.accessories.
2.3.3
Exhaust with separate
flues (ø 80)
"SOLO 30 BF -DUETTO 30 BF".boi-
lers. are. designed. to. be. connected.
KEY
1.
Exhaust.terminal.code.8089501
2.a. Stainless.steel.extension.L..1000
2.b. Stainless.steel.extension.L..500
3.a. 90°.stainless.steel.curve
3.b. 45°.stainless.steel.curve
4.
Stainless.steel.vertical.condensation.recovery.L..148
5.
Tile.with.hinge.code..8091300
6.
Roof.outlet.terminal
7.
Exhaust.kit.L..224.code.8098811
8.
Suction.terminal.code.8089500
9.
Internal-external.ring.nut.kit..code.8091500
TABLE B
.
90°.stainless.steel.curve.
45°.stainless.steel.curve.
Stainless.steel.extension.L..1000.
Stainless.steel.extension.L..500.
Roof.outlet.terminal.L..1063.
Exhaust.terminal.
Suction.terminal.
Stainless.steel.vertical.condensation.recovery..L..148.
1
2
9
2
3
8
9
2
max.16.m.equivalent.length
max 16 m equivalenti
WARNING:
The maximum length of the suction flue should not exceed 16 equivalent meters.
The maximum length of the exhaust flue should not exceed 6 equivalent meters.
For roof-mounted outputs, always use the condensation recovery (4) and verify that the maximum
vertical length of the flue does not exceed 7.6 meters without changes in direction.
to. separate. ø. 80. flues. in. stainless.
steel,.which.can.be.oriented.in.the.
position.that.best.suits.the.require-
ments.of.the.room.(figure.6/a):
-. Suction.flue:
. the. maximum. permitted. length.
of.the.flue.should.not.exceed.16.
equivalent.meters..
-. Exhaust.flue:
.
the. maximum. permitted. length.
of. the. flue. should. not. exceed. 6.
3
7
2
Load.loss.(mt)
1,00
0,60
1,00
0,50
1,00
0,40
0,10
1,50
8
9
2
max.16.m.equivalent.length
max 16 m equivalenti
equivalent.meters..
. For.
roof-mounted.
always. use. the. condensation.
recovery. and. verify. that. the.
maximum. vertical. length. does.
not. exceed. 7.6. meters. and. that.
there.are.no.direction.changes.
.
The load losses for each acces-
sory used in suction and exhaust
configurations are indicated in
2
6
2
5
2
4
7
3
2
outputs:.
3/10
Fig..6/a