Handling the battery.
Store, operate and charge the battery only
using FEIN battery chargers within the oper-
ating-temperature range between 5°C –
45°C (41°F – 113°F). At the beginning of
the charging procedure, the battery temper-
ature must be within the battery operating-
temperature range.
Battery charge-control indicator
(figure 5).
The charge condition can be indicated by the
green LEDs of the charge-control indicator
on the battery. Press the charge-control
indicator button
charge condition.
LED indicator Meaning
1 – 4 green
Percent-
LED
age of
charge
condition
Continuous
Battery is
red light
almost
empty
Red flashing
Battery is
light
not ready
for opera-
tion
The real percentage of the battery charge
condition is only indicated when the power
tool motor is stopped.
The electronics automatically switch off the
motor prior to the battery being deep dis-
charged.
When no LED lights up after pressing the
charge-control indicator button, the battery
is defective and must be replaced.
or
to indicate the
Activity
Operation
Charge battery
Bring the bat-
tery into the
battery operat-
ing-tempera-
ture range,
then charge
Fig. 5
80-100 %
60-80 %
40-60 %
20-40 %
5-20 %
0-5 %
en
19
60-100 %
30-60 %
5-30 %
0-5 %

Publicidad

loading

Este manual también es adecuado para:

Agsz18-280lbl asAgsz18-90lbl as