Description Of Menu Functions - Ravelli RBH 150 V Manual De Uso

Ocultar thumbs Ver también para RBH 150 V:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Rev.1 14/02/18
Pag.78
EN
The first setting allows you to enable the COMFORT CLIMA function which is aimed at checking that the temperature set for room/
water is maintained at the set value for a maximum period of X minutes (SHUTDOWN DELAY: 5 MIN) before switching to before
switching to ECO STOP phase. The stove remains in this state until the room or water temperature drops below the set value
(CLIMATE COMFORT DELTA : 5 ° C). The COMFORT CONTROL function allows the user to program the stove to switch off when
the set values of AIR temperature rather than WATER temperature are reached (set by the user).
For example, with the room temperature at 21 ° C, the stove switches off when this temperature is reached and restarts when the
temperature reaches 15°C (21°C - 5°C - 0.5°C tolerance).
For example, with the room temperature at 65°C, the stove switches off when this temperature is reached and restarts when the
temperature reaches 59 (21°C - 5°C - 0.5°C tolerance).
You can also activate the function using an external thermostat, keeping in mind that this does not include the value of the hysteresis.
We recommend you use an external thermostat with a histeresys value that can be set to maximum 3°C.
Stove's operation may enable the switch on/off phase for several times during the day; this may compromise the shelf life
of the ignition resistance.
DIFFERENT FROM THE MODELS THAT HAVE A AUTOMATIC CLEANER, USING THIS METHOD IT IS NECESSARY
TO VERIFY THAT AFTER EVERY AUTOMATIC SHUTDOWN THE BRAZIER ALWAYS WELL CLEANED IN ORDER TO
GUARANTEE A CORRECT AUTOMATIC IGNITION.
Stand-by
The STAND-BY mode is activated when the temperature of the water reaches 85 , this function is aimed at protecting the circuit
especially when COMFORT CLIMATE function is not active on boiler H2O. If the boiler is not in this condition
, it switches to STAND-BY mode to guarantee protection of the hydraulic circuit. The boiler restarts
automatically after it cooled down, on the condition that heating is requested.

Description of menu functions

Press the key to access the MENU page
The TECHNICIAN and MANUFACTURER menus are protected by password.
Chronothermostat
With the Chrono-thermostat function you can program the automatic switch ON/OFF of the stove for each day of the week for each
day of the week in 4 independent time intervals (SET CHRONO 1-2-3-4).Below are given the steps for accessing the relative menu
starting from Stand-By mode.
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"access menu" to
access the
MENU page
CHRONO
ENABLE CHRONO
SET CHRONO 1
SET CHRONO 2
SET CHRONO 3
SET CHRONO 4
CHRONO
ENABLE CHRONO
SET CHRONO 1
SET CHRONO 2
SET CHRONO 3
SET CHRONO 4
Use and maintenance manual RBH 150 V- RBH 200 V
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"confirm"
to access the
USER page
ENABLE CHRONO
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
to quickly switch to
CRONO-THERMOSTAT.
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
Press the key
several times
ENABLE CHRONO

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rbh 200 v