WAIT FOR PELLETS
INFEED SCREW
OVERFLOW
GENERIC ALARM
ANOMALY (general)
Warning Pop-Up
Adjust RDS
RD SYSTEM REGULATION
system
(only if the RDS system is
FLOW METER FAILURE
(only if the RDS system is
SERVICE REQUEST
SIGNALLING
• The door and the ash box are not closed correctly
CLEAN
• Poor combustion in grate.
THE GRATE
(only if the RDS
system is installed)
• Presence of foreign body in air intake tube.
• The air flow meter may be dirty.
La comparsa del messaggio "REGOLARE SISTEMA RDS" indica che la procedura di collaudo e taratura dei parametri
iniziale non è stata effettuata correttamente. Questa indicazione non implica il blocco della termostufa.
Use and maintenance manual RBH 150 V- RBH 200 V
PHASE
OFF
The stove is off
When the switch-on request from ECO-STOP mode coincides with an automatic switch-off
condition (from the TIMER), the stove turns on ensuring total cleaning of the brazier before
OUT OF
switching to FINAL CLEANING.
CONDITION: when the pellet setting (set pellets +5) is near the continuous load condition.
SOLUTION: Set the value back to 0.
The stove is in alarm state; refer to the troubleshooting chapter.
The stove has detected an anomaly; refer to the troubleshooting chapter.
Forced shutdown state when the boiler water reaches 85°C. The stove restarts automatical-
STAND BY
ly if the restart conditions are met.
ANOMALIA
It shows that the testing procedure and initial parameter calibration have been completed
REQUEST
incorrectly.
This indication, however, does not block the stove.
installed)
It shows a failure of the air flow meter and the stove switches to minimum capacity
disabling the RDS system.
installed)
The threshold value of set work hours has been reached. The symbol displayed remains
active throughout the work phase. Non-routine maintenance is required on the stove.
REASON
DESCRIPTION
DESCRIZIONE
SOLUTION
• Make sure they are closed properly.
• Switch off the stove, clean the brazier and check the cleanliness of the
support bench, clean the tube bundle by activating the turbolators and adjust
the combustion through pellet/air settings.
• Check if present and remove foreign body
• Clean the flow meter with the stove in "Switched off" state
• Contact the Support Service