1
4
5
By pressing the Increment key you can change each value and, at step 3, enable the days of the week;
By pressing the Increment key you can change each value and, at step 3, enable the days of the week;
Press "confirm" to confirm the settings and switch to the next value;
Press the "back" button to return to the CHRONO-THERMOSTAT page.
As per the above example, it has been set as CHRONO 1 an ignition from 08.30 to 21.30 from MONDAY to FRIDAY with room
temperature set to 21°C and hot water temperature set to 51°C.
Follow the same steps to set the programs 2-3-4.
To exit the CHRONO-THERMOSTAT function and return to Stand-by page, press the button repeatedly.
AIR / PELLETS setting
Setting of the PELLET-FLOW mix enables you to immediately change the quantity of pellet loaded in the brazier and the air inflow.
The stove is tested and approved with DIN PLUS certified pellets. If non-certified pellets are used you may need to regulate
combustion. Usually, the variation involves the FLOW percentage to regulate the air inflow and therefore combustion; if the flow
regulation is not sufficient, it may be required to change PELLETS feeding rate as well.
Below are given the steps for accessing the relative menu starting from Stand-By mode.
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"access menu" to
access the
MENU page
As per the above example, you have set a percentage of -2 for PELLETS and +3 for the FLOW, an indication that a setting like this
is a consequence of the fact that the oxygen needed for combustion is insufficient and pellet size is smaller than the average size of
2 cm.
To exit the SET AIR - PELLET function and return to Stand-by page, press the button repeatedly.
NOTE: The number indicated during the change of parameters refers only to a percentage value that acts on the default
parameters set on the electronic board (exclusively in the WORK phase). These values must be changed in the event of
poor combustion, due in many cases to the purchase of pellets differing from those used during stove testing.
Use and maintenance manual RBH 150 V- RBH 200 V
Press the key
"confirm"
to access the
USER page
Pellet
Flow
Pellet
Flow
2
1
Orario di accensione impostabile
2
Orario di spegnimento impostabile
3
3
Giorno della settimana con programma
attivo
6
4
Numero programma "crono" (1-2-3-4)
5
Settaggio della temperatura ambiente
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
SET AIR / PELLETS.
Pellet
Flow
Pellet
Flow
Rev.1 14/02/18
Page 79
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
Press the key
several times
to quickly switch to
EN
.