On the transformer, two faston terminals are provided, indicated as F1 and F2 in Fig.15.
Faston F1 (white) regulates the opening and closing speed of the door and can be preset on three voltage positions:
• 20V: for sectional and balancing doors (5.4 m/1')
• 28V: for sectional doors only (8 m/1')
• 35V: for sectional doors only (10 m/1')
Faston F2 (red) must not be moved from 20V position.
WARNING!: The adjustment of the door movement speed affects the safety level of the automatic system
JM.CB Emergency Battery Kit:
It permits the operation of the automatic system in the event of power failure.
The kit is composed of: battery charge card, 2 batteries at 12V, fitting bracket, screws and cables.
The batteries must be installed on the upper part of the gear motor basis, as per Fig.16.
To connect batteries, please refer to specific instructions.
Note: Once installed, the batteries protrude from the track upper profile by approx. 10mm.
JM.PP Cord Manual Control:
It permits the control of the automatic system from indoor by means of a cord, thus avoiding the installation of a key-
board. The kit is composed of: micro-switch group, cord control with knob, spring and cables (Fig.17)
For the installation, please refer to specific instructions.
Fig.19 shows the cord in working position.
In sectional doors, the system can be released also from outdoor by using item JM.SF (Fig.19).
A. Insert the metal cable in the slide, as indicated in Figure 19.
B. Fit the adjuster on the bracket and insert the sheath.
C. Fix the other end of the cable to the release device. The figure shows an example of connection to the garage door handle
AU.MS.
N.B.: Any type of cord release device can be used under the condition that the release stroke is of at least 15
mm.
If the device is able to keep the lever in the release position (e.g. AU.MS) it would be easier to cut the hooking lever,
as shown in the detail of Fig. 19. In this way, by moving the handle in the original position, the automatic operation is
reset.
Overhead door with balanceweights (fig.20): these doors need the special arm art. AU.C25.
In order to assemble it make sure that:
• the arm is fixed to the top edge of the door.
• the arm is levelled.
The civil liability policy, which covers possible injuries to people or accidents caused by defects in construction, requires
to use original Benincà accessories.
18
4. How to regulate speed
Comply with regulations in force
5. Accessories (optional)
6. Manual operation from outdoor
7. Assembling onto balancing doors