Descargar Imprimir esta página

RIDGID K-750 Manual Del Usuario página 18

Limpiadora de desagües
Ocultar thumbs Ver también para K-750:

Publicidad

Idiomas disponibles

Idiomas disponibles

K-750 Drain Cleaning Machine
Figure 16 – Removing AUTOFEED
3. Push down on motor table to release belt tension
and slip belt off of the drum. See Figure 17.
Figure 17 – Releasing Belt Tension
16
Push Down
Motor Table
4. Use
3
/
" wrench to remove the bolt that holds the
4
drum to the machine frame. See Figure 18.
Figure 18 – Removing Drum Bolt
5. Lay machine on it's back (see Figure 19). Use proper
lifting technique to lift the drum off of its mounting po-
sition. A drum with 100' of cable can weigh as much
as 150 pounds. In some cases, two people will be
needed to handle a drum of cable.
Figure 19 – Removing Drum