6. Technical data
General data
Power dissipation
Max. switching frequency (pulse/pause times 50:50) 2 Hz
Service life
Degree of protection
Ambient temperature range
Rated surge current between
control input, control supply and switching voltage
• Nominal mains voltage (≤ 500 V AC)
• Nominal mains voltage (≤ 300 V AC,
For example, 230/400 V AC, 277/480 V AC)
• Nominal mains voltage (300...500 V AC)
Control input, control supply voltage and reply output
Reply output and switching voltage
• Nominal mains voltage (≤ 500 V AC)
• Nominal mains voltage (≤ 300 V AC,
For example, 230/400 V AC, 277/480 V AC)
• Nominal mains voltage (300...500 V AC)
Rated surge current between
control input, control supply and switching voltage
• Nominal mains voltage (≤ 500 V AC)
Control input, control supply voltage and reply output
Reply output and switching voltage
• Nominal mains voltage (≤ 300 V AC,
For example, 230/400 V AC, 277/480 V AC)
• Nominal mains voltage (300...500 V AC)
Surge voltage category
Pollution degree
Standards/specifications
Coordination type
Mounting position
Mounting
Housing:
Connection data (conductor cross-section)
Screw terminal blocks (solid/stranded)
M3 thread, recommended torque
Weight
Conformance / Approvals
acc. to UL 508/UL 60947-4-1A/UL 60947-1 NLDX File: E228652
EU examination certificate
Safety level
min./max. 0.88 W/2.5 W
Operation
Transport, storage
Power station requirement
(refer to 8.2. Derating curves) Can be aligned with ≥ 20 mm spacing
Dimensions (W / H / D)
as per ATEX X II (2) G [Ex e] [Ex d] [Ex px],
ELR...-0.6
7
3 x 10
cycles
IP20
-25°C to +70°C
-40°C to +80°C
6 kV (ELR H5-IES-24DC/...)
Safe isolation (EN 50178)
Safe isolation (IEC 60947-1)
Basic isolation (IEC 60947-1)
Safe isolation (IEC 60947-1)
Safe isolation (EN 50178)
Safe isolation (IEC 60947-1)
Basic isolation (IEC 60947-1)
4 kV (ELR H5-IES-230AC/...)
Basic isolation (IEC 60947-1)
Safe isolation (IEC 60947-1)
Safe isolation (IEC 60947-1, EN 50178)
Basic isolation (IEC 60947-1)
III
2
IEC 60947-4-2 / IEC 61508-1 /
EN 954-1 / ISO 13849-1
DWR 1300 / ZXX01/DD/7080.8d
1
vertical (horizontal DIN rail)
Material
PA 66
(22.5 / 99 / 114.5) mm
See connection notes (page 15)!
0.14-2.5 mm
0.5 - 0.6 Nm / 5-7 lbs-ins
approx. 212 g
NMFT File: E323771
X II (2) D [Ex t] [Ex p]
PTB 07 ATEX 3145
See "7.1 Safe shutdown"
and "7.2 Motor overload protection"
ELR...-2
ELR...-9
0.88 W/4.1 W
0.88 W/7 W
2
(AWG 26-14)
21