reLiminary oPerations
1. Check that the electricity and water circulation are switched off. The valves on the pipes connecting
to the salt chlorinator must be closed.
2. Ensure any pipes used (not supplied) are compatible with the chlorinator.
Dimensions of the 2 types of connectars supplied:
• OPTION 1: connectors to be glued 1.5" (metric: Ø50 mm)
• OPTION 2: D32 or 38 mm push-in connectors
3. Clean up any clutter.
4. Lubricate the connectors
5. Ensure the direction of water flow corresponds ta the direction indicated on the chlorinator: ''
h
ydrauLic connections
The sait chlorinator must be installed on the return line carrying water from the pool filter back ta the return
inlets, as shown in FIGURE 1 (horizontal assembly) and FIGURE 2 (vertical assembly).
If using with a water heating system, install the chlorinator downstream from the latter.
The chlorinator must be the final element of the circuit.
Installation without a bypass is possible if your pump has a flow rate of < 10m
"bypass" is strongly recommended ta allow the hydraulic circuit ta be isolated.
If the flow rate of your pump is > 10m
FIGURE 1
|
28
EN
/h, a bypass is required.
3
INSTALLATION
3
''.
/h, however, using a
FIGURE 2