5. Preparation for use
Place the TMBH 5 on a workbench or similar
(stable base)
Make sure the line voltage is within the specified
range of 100–240 V, 50–60 Hz. Connect the
mains plug to a suitable power supply.
Carefully place the workpiece to be heated at
the top of the bearing stand.
Then open the clamp and place it around the
workpiece.
Connect the heating clamp to the heater.
Never connect or disconnect the heating clamp
during operation.
The heater is designed to heat up one
component at a time.
If used in Temperature Mode, plug the
temperature probe into the connector.
Place the magnetic tip of the probe on the flat
surface of the bearing inner ring or on the
innermost surface of the workpiece.
It is then recommended to attach the probe
to the hottest part of the component which in
general is the part closest to the clamp.
Switch on the heater from the main switch,
which is located at the left side of the heater.
The power LED will be lit for few seconds until
the entire display and heater will be ready.
Select the right heating mode and settings.
Once you have finished heating the component,
attach the magnetic probe tip to the metal-
lic sheet on the heater's housing. This is the
temperature probe's parking spot, located at the
upper right of the heater.
9