8. Troubleshooting
It might happen that you encounter a failure in the
heater. If this happens, have a look to the following
options:
A system fault will be indicated by an acoustic
signal and one of the following fault codes on
the user interface display will be shown:
Error code
E00
E01
E04
E05
E06
E07
E08
E09
E010
E013
E014
Fault
Empty Clamp
- Clamp is open
- Non ferromagnetic workpiece like
aluminium or copper
Human Interface Failure
- Internal electronics or communication
problem
Power electronics overheated
- Too intense use without time to cool
down
Too slow temperature increase
- Temperature probe not attached to the
component
- Workpiece out of range (too big or heavy
for heating capacity)
Missing or Invalid Thermocouple
- Temperature probe not connected or
damaged
- Temperature probe removed during
operation
- Temperature probe still cooling down
from a previous heating job.
Power electronics failure
- Temperature sensor (power switches)
failed.
- Open/short circuit
Mains supply voltage out of range
- Eventual voltage peak
- Power supply out of tolerance (10%)
Clamp Removed/disconnected
- Clamp cable, connector etc. damaged
- Clamp not connected properly
Environment temperature too high
Config write failure
- Electronics problem
Config read failure
- Electronics problem
Action to fix it
- Close the clamp properly
- Put the right workpiece in the clamp
- Return to reseller
- Remove workpiece
- Switch off the heater to allow it to cool
down. The error will be automatically
cleared
- Otherwise, return to reseller
- Make sure that the thermocouple is
mounted correctly (to a flat, clean
surface)
- Check Thermocouple connection and
wire damage
- If damaged, use Time Mode and use an
external thermometer
- Do not remove the probe during
operation
- Allow some cooling time until
temperature probe reading stabilization.
- Reset the heater
- Replace power print
(send to reseller)
- Reset the heater
- Check mains supply for correct level
- Connect the clamp properly
- Replace the clamp
- Let the heater cool down
- Use the heater in low power mode
- Place the heater in right working
conditions (0-40°C)
- Try to reset the heater,
turn OFF and ON
- Try to reset the heater,
turn OFF and ON