Safety recommendations
Because the TMBH 5 generates a magnetic
field, people wearing a pacemaker or implants
must not be within 5 m (16 ft) of the TMBH 5
during operation.
During the heating process observe a safety
distance of 30 cm (1 ft) with the workpiece or
the heater. Electronic equipment, such
as wristwatches, cellphones, etc. may also
be affected.
Always follow the operating instructions.
Make sure that the power supply voltage does
not deviate from the acceptable range of
100 - 240V, 50 - 60Hz.
Use the right power level, especially with
shielded or sealed with metallic inserts
bearings. SKF does not recommend heating
bearings capped with seals or shields above
80 °C (175˚F). However, if higher temperatures
are necessary, please contact SKF. Small
bearings to be heated using low power mode,
25% or 10% to avoid risking overheating the
bearing.
Do not expose the TMBH 5 to high humidity,
outdoors or to flammable atmospheres.
Do not modify the TMBH 5. All repairs should
be taken care by SKF repair shops. Do not touch
a damaged heater if plugged to the mains.
The TMBH 5 is solely intended to heat up
bearings, gears, couplings and other industrial
annular components.
The heater needs to be operated by
professionally trained people.
Do not leave the heater unattended especially
when using time mode.
Avoid contact with hot surfaces. Always wear
protective gloves. In case of burnings ask for
first aid help if necessary.
Never heat to temperatures above
200 °C (392 °F).
The heater is designed for maintenance
operations where some cooling in between jobs
is allowed.
In case of fire, do not use water nor powder-
based extinguisher. This will damage the
electronics. A CO2 based extinguisher is
recommended, if available.
Be aware that fumes coming from the heated
element might occur.
Make sure that the component does not heat up
above any desired limit by properly measuring
temperature. If so, adjust the power level
accordingly.