Ram blow function: if=0 "Ram blow" function deactivated; if=1 it pushes the motors closed for one second
before each opening movement, so as to ease the releasing of any electric lock; if>1 it execute a periodic
pushing stroke so as to maintain the wings under pressure on the closing strokes. If closing limit switches
are installed, it performs this function only if they are not activated, i.g. when there's a pressure decrease
on the stroke.
"Reversal" mode selection (during the manoeuvre a command impulse reverse the mouvement) or "step by
step" (during the manoeuvre a command impulse stops the mouvement). A next impulse restart the operator
to the opposite direction.
Operation mode selection of the warning light output:
If = 0 "warning light" (output always ON when the gate is open, OFF after a closing operation),
If = 1 "fl ashing warning light" (slow intermittent output during opening and fast while closing, always ON at
gate opened, always OFF at the end of a closing operation only),
If> 1 "courtesy light" (output ON during each movement, OFF when the motor stops, after the setting delay)
Searches for end of stroke while opening too: when activated, operators stop only at their arrival et the end
of stroke, also while opening.
Warning: During the emergency operation (rESP), the motor executes the fi rst maneuver while opening. In
addition, if any limit switches, the parameter is forced to 1.
"soft start" function: motors accelerate gradually until they reach the set speed, avoiding sudden departures
ONLY TYPE 02: If=3 the opening slow space (P035) also becomes the space within which the port moves at
slow speed (P031) and close start.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the opening.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the closing.
Facilitation manual release: If≠0, after ending the closing or opening maneuver, the engine reverses for
a brief time to release the pressure on it, and thus facilitate the manual release. The set value shows the
length of the inversion. If=0 function disabled
TYPE 00 - 01 - 03 ONLY: Adjustment of the opening stroke margin: it adjusts the duration of the last part of
the stroke during which an obstacle is interpreted as a stroke, blocking the motor without performing the
inversion.
For motors with encoders, the set value indicates the number of revolutions of the rotor; while for motors
without encoder, the value is expressed in% of the maximum stroke.
Warning: for motors without encoder, if P035 (duration slow-down while opening) is >10%, it forces the
stroke detection margin so that it's the same than the slow-down.
TYPE 02 ONLY: Duration adjustment for the secondary force in closing: adjusts the duration of the last part
of the closing movement, in which the force is managed separately with P039. The value is expressed in
number of revolutions of the rotor.
EN-24
PHOTO input functioning: If=0: photocell enabled while closing and starting when the gate is
stopped; if=1 photocells are always enabled; if=2 photocells are enabled while closing only.
PHOTO 1
When enabled, its activation provokes: the inversion (while closing), the stop (while opening)
and prevent the starting (when gate is closed).
If = 3-4-5, the operation is identical to values 0-1-2 but with the" close immediately "function
PHOTO 2
enabled: in any case, when opening and / or pausing time, removing a any obstacle the gate
will end the opening maneuver before closing it automatically after a 2 second fi xed delay.