OPERATING INSTRUCTIONS
Digital output
Output current I
Circuit protection
Response time
Repeatability (response time)
Switching frequency
1)
A = U
B = inputs and output reverse-polarity protected
C = Interference suppression
2)
Signal transit time with resistive load
3)
Valid for Q\ on Pin2, if configured via software
4)
With light / dark ratio 1:1
Mechanical data
Enclosure rating
en
Ambient temperature, operation
11.2
Dimensional drawings
62
O P E R A T I N G I N S T R U C T I O N S | WTM4S
max.
-connections reverse polarity protected
B
12.1
(0.48)
3
1
2
4
Figure 13: WTx4SP, cable connection
Preferred direction of the target object
1
Center of optical axis, receiver
2
Center of optical axis, sender
3
Connection
4
M3 threaded mounting hole
5
Display and setting elements
6
WTM4S
≤ 100 mA
A, B, C
1)
≤ 500 µs (MultiMode 1, 2, 3)
≤ 1,000 µs (MultiMode 4, 5)
≤ 15 ms (MultiMode 1 + 6)
150 µs (MultiMode 1, 2, 3)
350 µs (MultiMode 4, 5)
3)
5 ms (MultiMode 1 + 6
3)
1,000 Hz (MultiMode 1, 2, 3)
500 Hz (MultiMode 4, 5)
4)
30 Hz (MultiMode 1 + 6)
4)
WTM4S
IP69K
-20C...+55 °C
18.6
5
8.9
(0.35)
12
(0.47)
Subject to change without notice
2)
2)
2)
3)
4)
(0.73)
6
5
5
8028212/2023/10/20 | SICK