Install Your Outdoor Unit
1
Select installation location
NOTE : PRIOR TO INSTALLATION
Before installing the outdoor unit, you must choose an appropriate location. The
following are standards that will help you choose an appropriate location for the
unit.
Proper installation locations meet the following standards:
60cm 24"
above
30cm 12"
on left
200cm 79"
in front
Meets all spatial requirements shown in Installation
Space Requirements above.
Install the unit by following local codes and regulations , there may be
NOTE
differ slightly between different regions.
CAUTION:
SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the direction of the wind. If
needed, build a barrier in front of the unit to protect it from extremely heavy
winds. See Figures below.
If the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be careful not
to obstruct air flow around the unit.
If the unit is frequently exposed to salty air(seaside):
Use outdoor unit that is specially designed to resist corrosion.
Strong
wind
90° angle to the
direction of the wind
DO NOT install unit in the following locations:
Near an obstacle that will
block air inlets and outlets
Near a public street, crowded
areas, or where noise from
the unit will disturb others.
30cm 12"
from back wall
Good air circulation
and ventilation.
60cm 24"
on right
Protected from prolonged periods
of direct sunlight or rain.
Strong
wind
Build a wind Baffle
to protect the unit
Near animals or plants
that will be harmed
by hot air discharge.
Near any source of
combustible gas.
Firm and solid—the
location can support the
unit and will not vibrate.
Long-term
Wind Baffle
Strong
wind
In a location that is exposed to large
amounts of dust
In a location exposed to a excessive
amounts of salty air.
32
Noise from the unit
will not disturb other
people.
Where snowfall is anticipated, take
appropriate measures to prevent
ice buildup and coil damage.
Shelter
Build a shelter
to protect the unit
V.1