FOR THE MODELS EQUIPPED WITH MULTIFUNCTIONS LCD CONTROL UNIT
The thermostat allows to control the temperature by
ON-OFF or PID algorithm and the incubation humidity
by ON-OFF mode.
At the starting, it will appear on the display for some
seconds the software version.
On the main working window it is showed the current
values of temperature and relative humidity, inside the
incubator and those ones set up as working values.
It is also possible to regulate the speed fan.
DESCRIPTIONS OF THE FUNCTIONS:
In case of reading error of temperature or humidity
probes, it will be showed asterisks (**). The electronic
instrument has two menus for setting parameters, one
for the user, where it is possible to program the basic
functions and the technical one which allows the instru-
ment configuration.
USER MENU
Pressing 'Set', you enter into User menu, where it is possible to set the working temperature of the PID system, the alarm temperature and the %
relative humidity to be maintained during the incubation period. It is possible to view all the parameters pressing the key "set", to modify the selected
parameter, use the keys
and
pressed for longer than about 25 Sec.
USER LIST PARAMETERS MENU
• Unit Measur temp [°C,°F] (default °C) Setting units of measurement degrees Celsius / Fahrenheit
• Incubation temp.
(default 37.7)
• Alarm temperatur
(default 38.5)
• Incubation humid
(default 47)
Speed fan Regulation ( only for model MG244)
Press the key "Fan" to enter in the speed fan set up, choose the value
1,2 or 3 by the keys
and
key "Fan".
Technical menu
Pressing simultaneously both the keys
It is possible to view all the parameters pressing the key "set", to modify the selected parameter, use the keys
The electronic instrument will automatically exit the programming menu if no keys are pressed for longer than about 25 Sec.
The LCD control unit is equipped with 6 different incubation programs as follows:
GENERIC (0)
INC.PALMIPEDS (1)
DIAPAUSE (2)
CAM/CLIME (3)
GERMINATOR (4)
EXOTIC (5)
REP/TORTUGA (6)
In order to display on the display the various incubation programs press the button and hold it
"(incubation program),
key
run all incubation programs
key
to enter the parameter settings of the selected program
keys
and
to adjust the parameters
key
to store the settled parameter
Master
switch
Light
switch
and memorize by "set". The electronic instrument will automatically exit the programming menu if no keys are
This parameter determinates the temperature that the instrument must be maintained during incubation
period. The range of the values that can to be setted in this scale is definited by the parameters "Inc.
temp.min." and "Inc.temp.max." showed in the technical menu.
If the read temperature by the instrument reaches the setted one in this parameter, it will be switched
on the acustic buzzer alarm in order to report a fault. This out will remain on until the temperature does
not decrease under the setted value – "Ist.temp.allarm.". The range of values that can to be setted in this
scale is definited by the parameters "Temp.alarm.min." e "Temp.alarm.max." showed in the technical
menu.
This parameter allows to set the relative humidity to be maintained during incubation period. The range
of setting values in this scale is definited by the parameters "Min.Humidity" and "Max.humidity" showed
in the technical menu.
, and confirm pressing again the
+
, you will access the "Technical menu".
The default is set by the factory on the program GENERIC (0)
Relative humidity
reading
Temperature
reading
Relative
Temperature set
humidity
point
set point
Speed 1 = lower speed suggested for breeding the animals for the first week of life
Speed 2 = medium speed suggested for hatching period (last 2 days)
Speed 3 = maximum speed suggested during incubation period
P
Fan speed
set value
Increase
Decrease
and
and memorize by "set".
pressed for 5 sec., it will appear "Cycle Mode
Mode
(Calendary)
Speed fan
regulation
Parameters
selection
17