Technical List Parameters menu
• Unit Misura temp
• Hour format
• Set Hour
• Inc. temp. min.
• Inc. temp. max.
• Alarm temp. min.
• Alarm temp. max.
• Alarm temp.hyst.
• Calib temp.probe
• Humidity min.
• Humidity max.
• Humidity hyst.
• Cal.humid.probe
• Language
• Type of fan
Fan motor type
1
2
3
• Buzzer Mode
• Cam Cycle Time
• Cam Time
• Cam Time
• Light ON Time
• Light OFF Time
• Default parameter VENT. to reset
INDICATIVE CONVERSION TABLE FROM FAHRENHEIT DEGREES (°F) TO CELSIUS (°C).
°F
°C
80
26,7
81
27,2
82
27,8
83
28,3
84
28,9
85
29,4
LCD THERMOSTAT INCUBATION CALENDARY
Once one or more hatching cycles calendars are activated, the display will show, further than temperature and humidity values, the counting of the
total number of days & hours spent from the begin of the first hatching cycle.
Pressing the "P" button you will accede to the hatching cycles programming menu. The display will show different indications according to the state
of the running incubation cycle. If the cycle is not activated
By repeatedly pressing the 'P' button you will run through the 4 incubation cycles. Pressing the 'SET' button you can start or stop the cycle of incuba-
tion displayed. It will be possible to "force" the display of a particular cycle, including those active on the working screen (so not only the cycle started
by longer) by pressing the' P ' key until you reach the cycle to be displayed, and letting the tool go to time-out (about 30 Sec).
18
[°C,°F] (default °C)
Setting units of measurement degrees Celsius / Fahrenheit
24h AM / PM
Current time setting (hours and minutes)
[5,0 .. 75,0] (default 25.0) Used to limit the minimum acceptable value in the parameter incubation temperature
User Menu
[5,0 .. 75,0] (default 40.0) Used to limit the maximum acceptable value in the parameter incubation temperature
User Menu
[5,0 .. 75,0] (default 30.0) Used to limit the minimum acceptable value in the parameter alarm temperature
User Menu
[5,0 .. 75,0] (default 40.0) Used to limit the maximum acceptable value in the parameter alarm temperature
User Menu
[0,1 .. 5,0] (default 0.1)
Used to set up hysteresis (accuracy) of alarm temperature
[-3,0 .. +3,0] (default 0.0) Used to calibrate the probe of temperature
[10 .. 90] (default 40)
Used to limit the minimum acceptable value in the parameter incubation humidity
User Menu
[10 .. 99] (default 80)
Used to limit the maximum acceptable value in the parameter incubation humidity
User Menu
[1 .. 20] (default 1)
Used to set up hysteresis (accuracy) of thehumidity regulation
[-5 .. +5] (default 0)
Used to calibrate the probe of humidity
[0 .. 1] (default 0)
Used to choose the languages showed on the display (Italian / English)
[1 .. 4] (default 1)
Used to choose the motor fan model
Incubator model
MG50-MG70-MG100-MG140
MG244
MG500-432-576-720-MG400H
[0 .. 2] (default 2)
Used to set the operating mode of the buzzer.
• 0 = Buzzer off
• 1 = Buzzer on for pressing the keys
• 2 = Buzzer on for pressing the keys and in case of high temperature alarm
ON-OFF cycle time (minutes)
ON ON time (minutes)
OFF OFF time (minutes)
Light time ON logic output – LIGHTS
Light time OFF logic output – LIGHTS
Setting of default parameters/Pressing the FAN button all default parameters are set
°F
°C
°F
86
30,0
92
87
30,6
93
88
31,1
94
89
31,7
95
90
32,2
96
91
32,8
96,8
Take note that 1°F is equal to 0,56 °C, while 1°C is equal to 1,8 °F.
Ciclo: Z ---d --h
SET=Inizio Ciclo (Z = number of the visualized cycle)
If the cycle is activated Ciclo:Z XXXd YYh
SET= Fine Ciclo_
°C
°F
°C
33,3
97
36,1
33,9
98
36,7
34,4
98,6
37,0
35,0
99
37,2
35,6
100
37,8
36,0
100,4
38,0
°F
°C
101
38,3
102
38,9
102,2
39,0
103
39,4
104
40,0
105
40,6