Unit configuration
10. Unit configuration
A local connection is required to configure the unit for the first time. Once this first configuration has been carried
out, a remote connection can also be established. The processes for both cases are described below.
The configuration is done through the INGETEAM WEB Manager application.
10.1. Local connection
To establish a local connection the charger and computer must be connected to the same communication network.
The local connection can be done through an Ethernet or Wi-Fi network.
10.1.1. Local connection via Ethernet
CAUTION
The Ethernet cabling must be category 5E or higher.
To make the connection, follow these steps:
1.
Connect the computer to the unit using one of the available Ethernet connectors at the bottom of the
charger.
2.
On the laptop, open the browser and go to http://192.168.1.33:8080.
3.
Enter the username and password. The username and password are specified on the documentation
delivered with the unit.
4.
Follow the instructions given by INGETEAM WEB Manager.
CAUTION
If it does not have a public IP, the computer and the charging point will need to be in the same network or APN.