R/L1/L
Power
Filter RFI
supply
S/L2/N
1
Digital inputs
(DI1 to DI4)
Analog input (AI1) 2
Preload
Single-phase
rectifier
PE
Power
Control
Sources for electronics and interfaces
between power and control
HMI
1
Available as accessory.
2
The number of inputs/outputs depends on the I/O expansion accessory used.
Figure 2.1: CFW100 block diagram for frame size 220 V
Rsh
DC link
Inverter
capacitor
with IGBT
bank
transistors
RS-485
1
Interfaces (RS-232,
RS-485, USB,
Control
CANopen, Devicenet,
Profibus DP)
board
with CPU
16 bits
Flash Memory
Module 1
General Information
U/T1
V/T2
Motor
3~
W/T3
PE
HMI (remote) 1
PC
Software
1
WPS
Analog output
(AO1) 2
Digital output
DO1 (RL1) 2
CFW100 G2 | 9