FAULTS
The appliance has been tested before com-
missioning. The information provided below
is intended to help identify and correct any
anomalies and malfunctions which might oc-
cur during use.
Some of these issues may be resolved by the
user, whereas other issues require specifi c
technical knowledge or skill, and therefore
they must be dealt with by qualifi ed staff with
Issues
The heating elements do
not come on
The appliance does not
reach the set temperature
The control panel does
not light on
Alarms
Safety thermostat probe
E00
Cooking well probe failure
E01
Cooking well probe failure
E.01
Cooking well probe failure
E02
3443260_ut_GB
FAULTS
TROUBLESHOOTING
Causes
Incorrect electrical connec-
Safety thermostat tripped
Contactor not powered or
faulty
Printed circuit board not
powered
ALARM TABLE
Causes
failure.
(LHS well)
(LHS well)
(RHS well)
recognised experience acquired in the specifi c
sector of operation.
NOTE: For any need, please contact
Angelo Po's agents or headquarters, which
can be found in the contacts section of the
website www.angelopo.com.
tion
Reset the appliance (see page 21)
mostat and activate any ignition
No cooking cycles can be executed as the appliance
functions are disabled. Reset the safety thermo-
stat (see page 21); if the problem persists, call the
after-sales service.
No cooking cycles can be executed as the appliance
functions are disabled.
NOTE: Contact the after-sales service.
No cooking cycles can be executed as the appliance
functions are disabled.
NOTE: Contact the after-sales service.
No cooking cycles can be executed as the appliance
functions are disabled.
NOTE: Contact the after-sales service.
ENGLISH
Remedies
Check the connection of the
electrical wires
Check the condition of the ther-
enabling device.
Check or replace the contactor
coil
Check or swap the phase wire
connections
Remedies
25