Descargar Imprimir esta página

Hitachi YUTAKI S COMBI Serie Manual De Instrucciones página 38

Ocultar thumbs Ver también para YUTAKI S COMBI Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
UNIT INSTALLATION
!
C A U T I O N
Four people are required when lifting because of the heavy weight
of the unit.
Be specially careful with the mounting feet once the unit is on the
floor. Avoid harsh handling of the unit, as it could cause damages to
the foot.
Each mounting feet can be adjusted up to 30 mm, but keep all them
in the factory-supplied position until the unit has been installed in its
final position.
6.1.3 Factory-supplied indoor unit components
Accessory
Image
Shut-down
valve
(2-3HP: 1")
(4-6HP: 1-1/4")
Gasket
CD-ROM
Instruction
manual
Instruction
manual
Declaration of
-
conformity
?
N O T E
The previous accessories are supplied inside the indoor unit, and
are accessible from top of the unit, once the carton cap has been
removed.
Additional refrigerant piping (field supplied) for connections to outdoor
unit needs to be available.
If some of these accessories are not packed with the unit or any
damage to the unit is detected, please contact your dealer.
6.1.4 Indoor unit main parts (Descriptions)
Part
1
Indoor unit front cover
2
Indoor unit left cover
3
Indoor unit right cover
4
Unit controller frame
5
Unit controller
6
Piping connections
20
PMML0573 rev.1 - 07/2021
Qty.
Purpose
To make easier the installation
work in the space heating
2
water inlet/outlet connections.
For a better servicing.
Two gaskets for each space
heating inlet/outlet connections
6
and another two for each DHW
inlet/outlet connections
With the detailed Installation
1
and operation manual
Basic instructions for the
1
installation of the device.
Additional safety manual for
R32 refrigerant air conditioner
1
and heat pump according to
IEC 60335-2-40:2018
1
-
6
2
1
6.2 REMOVING THE COVERS
If it is necessary to access to the indoor unit components,
please follow these operations.
6.2.1 Removing the indoor unit covers
?
N O T E
Front cover needs to be removed for any task inside the indoor unit.
Back, left and right covers do not need to be removed.

Removing the indoor unit front cover
1 Remove the 2 screws of the indoor unit front cover.
2 Slide the service cover slightly upward and remove it pulling
to back.
!
C A U T I O N
5
4
Pay attention of no falling off the service cover.
Take care when removing service cover; the parts inside the unit
could be hot.
3

Publicidad

loading