Descargar Imprimir esta página

cecotec BOLERO DRESSCODE 8800 INVERTER A Manual De Instrucciones página 98

Lavadora de carga frontal

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
ENGLISH
2. Secure the power cable to the rear of the appliance.
Levelling the washing machine
-
The appliance reaches high spin speeds to remove water at the end of the wash cycle.
-
Therefore, it is important that it is level and that all 4 legs press against the floor with the
same pressure.
-
This will help to ensure quieter operation and less vibration.
Carry out the following steps:
-
Install the appliance on a solid, level surface. Preferably in a corner of the room.
-
If the floor is uneven, adjust the legs as necessary to level the device. Do not place any
objects under the legs in an attempt to level it.
-
Do not extend the legs more than necessary. The more extended, the more vibrations the
device will suffer. Start with the legs all the way in and adjust each one as necessary.
-
You can use a spirit level (not included) to check that the appliance is level.
-
Press down on each corner of the top of the equipment to ensure that it does not "wobble".
-
All legs must press equally against the floor.
-
When the device is level and does not wobble, lock the legs by tightening the lock nuts
against the bottom of the equipment. Be sure to do this without changing the height of the leg
(hold the leg while tightening the lock nut). Fig. 5
Connection of the supplied hoses
Water supply hose connection
-
Connect one end of the water supply hose to a cold water tap and tighten by hand (Fig.
6). Before making the connection, allow the water to run freely until it runs completely clear.
-
Connect the other end of the water supply hose to the water inlet valve at the rear by
turning clockwise (Fig. 7).
-
Open the tap slowly and make sure there are no water leaks.
Warning
-
Do not kink, crush, modify or sever the water inlet hose.
-
Squeeze the end of the hose firmly by hand.
-
The water supply pressure must be within a range between 0.03 and 1 MPa. If the pressure
exceeds this value, a pressure reducing valve (not included) must be installed.
-
If the hose is not long enough, please contact a specialised retailer, an authorised
technician, or the Cecotec Service Centre.
-
Never use a second-hand or used hose. Always use the hose supplied with the equipment.
Drain hose connection
-
Drainage point height (Fig. 8)
98
BOLERO DRESSCODE 8800 INVERTER A / INVERTER STEEL A / INVERTER ICE BLUE A

Publicidad

loading