Replace or rearm the thermostat.
If the thermostat trips, rearm it and investigate the cause of the trip (short circuit, defective thermostat etc.).
WARNING: A thermostat is meant to be rearmed two or three times at the most.
Replacing the heating element
Check the ohmic value of the heating element and change it if necessary. If the value is null or infinite, the
heating element must be replaced.
Heat immersion range (THER)
The appliance must be drained to enable the replacement of the armoured heating element.
Steatite range
There is no need to drain the appliance to replace the heating element.
This product complies with the REACH directive on materials that come into contact with water
destined for human consumption.
V.
Preamble: The stipulations below may not be used to reduce or invalidate the statutory guarantee against
hidden defects (Art. 1611 et seq. of the Civil Code).
Given the technical nature of the product and in order to ensure the protection and safety of the consumer,
the electric water heater must be installed, commissioned, and regularly serviced by a qualified
professional in accordance with regulations, applicable standards, and the stipulations in the installation
manual. The appliance must be used in the normal manner in accordance with regulations, applicable
standards, and the stipulations in the installation manual.
The product was developed and is guaranteed for domestic installation and use.
If you intend to use the product for industrial/non-domestic use, you must contact the manufacturer
beforehand to safeguard the guarantee and ensure that the appliance works properly in the planned
application.
Given the technical nature of the product, repairs under guarantee must be performed by an authorised
professional. The manufacturer does not accept any liability for repairs performed and spare parts
provided by other professionals than the manufacturer or qualified professionals of the manufacturer.
LIMITS OF THE GUARANTEE
EN
34
Thermal safety