To draw out the light to the edge of the swimming pool, the trim ring should be removed with the help of a
screwdriver, through the four grooves on the trim ring (fig. 26) (p. 75). Remove the 6x20 screws (no. 11) (p. 10)
(fig. 27) (p. 75). Draw out the light to the edge of the swimming pool. Dismantle the light, removing the nuts (no. 15)
(p. 10) which secure the trim ring (no. 2) (p. 10) to the screen and flange set (no. 5) (p. 10) in order to gain access
to the lamp (fig. 28 and fig. 29) (p. 75). Pull the lamp (no. 7) (p. 10) (fig. 30) (p. 75) to separate it from the lamp
holder (no. 13) (p. 10) and connect the new one (fig. 30) (p. 75).
VERY IMPORTANT: to change the lamp, always use the cardboard protector and never touch the new lamp
with bare hands.
Assemble the light using a screwdriver in the opposite order to the procedure described. Do not tighten the cable
under any circumstances.
CAUTION
The new lamp must have the same characteristics as the one supplied with the light: halogen 100 W 12 V
(AC).
To ensure complete watertightness, the seat of the light lens O-ring should be cleaned (no. 4) (p. 10) or
replaced if any notching or permanent deformities are observed.
PREPARING THE EQUIPMENT FOR WINTER
It is recommended that the equipment is prepared for winter or for a prolonged period when it is not in use. To do
this, follow these steps:
Place the pump switch in the OFF position (disconnection) (fig. 21) (p. 74).
Empty the filter, pump and water pipes.
CAUTION
• If the surface of the swimming pool freezes up, it is advisable to remove the front module from the swimming pool
to avoid damage.
7. TROUBLESHOOTING
PROBLEM
The equipment does not
circulate the water.
The equipment circulates only
a little water.
The pump does not prime.
The housing fills with water.
The filtration module fills with
water when the pool is
emptied.
The lamp does not light up.
REASONS
No electrical power.
Motor protector is not properly
adjusted.
The filter is dirty
Pre-filter of the pump or skimmer
is blocked.
Air enters the suction pipe.
Water level of the swimming pool
is insufficient
Incorrect voltage.
Air intake.
The drain of the box has not
been installed.
The pump drains and waste
drains are connected to one
another.
No electrical supply.
The lamp has blown.
Pneumatic switch is
disconnected.
8 of 80
SOLUTIONS
Check the electrical connection and
ensure that electricity reaches the
socket.
Check the pump consumption and
adjust the motor protector on the
control panel.
Clean the filter.
Clean the pump pre-filter or the
skimmer basket.
Check the condition of connectors
and suction pipe joins.
Fill the swimming pool until the
water covers half the hinged gate of
the skimmer.
Check that the mains voltage
matches the voltage indicated on
the motor's rating plate.
Check all pipe connections and the
pump cover. Fill the pre-filter of the
water pump.
Install a drain to remove water from
the box.
Change the installation of the
drains so that each has its own
drainage pipe.
Check that it is properly connected.
Change the lamp.
Check that the switch tube is
correctly connected.