Descargar Imprimir esta página

Bosch GAS 12-40 MA Professional Manual Original página 20

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
20 | English
mediately and empty the container. Otherwise, the va-
cuum cleaner can become damaged.
NOTE: The vacuum cleaner must only be stored in-
u
doors.
NOTE: Clean the liquid fill level sensors regularly and
u
check whether they are damaged. Otherwise, the
equipment may not function properly.
If operating the vacuum cleaner in a damp location is
u
unavoidable, use a residual current device (RCD). Use
of an RCD reduces the risk of electric shock.
Always check the vacuum cleaner, cable and plug be-
u
fore use. Do not use the vacuum cleaner if you dis-
cover any damage. Do not open the vacuum cleaner
yourself. It should be repaired exclusively by a quali-
fied professional using only genuine spare parts. Dam-
aged vacuum cleaners, cables and plugs increase the risk
of electric shock.
Do not crush the cable or run the device over it. Do not
u
pull on the power cable to pull the plug out of the
socket or to move the vacuum cleaner. Damaged
cables increase the risk of an electric shock.
Pull the plug out of the socket before cleaning or per-
u
forming maintenance on the vacuum cleaner, making
tool adjustments, changing accessories or putting
away the vacuum cleaner. This safety measure prevents
the vacuum cleaner from being started accidentally.
Ensure that the workplace is well ventilated.
u
The vacuum cleaner should be repaired exclusively by
u
a qualified professional using only genuine spare
parts. This will ensure that the safety of the vacuum
cleaner is maintained.
If the dust extractor is being used in areas containing
u
hazardous substances, then vacuum, wipe or seal the
outside of the dust extractor before taking it out of
the hazardous area. All parts of the dust extractor are
deemed contaminated and you must ensure appropriate
measures are taken to prevent the hazardous substances
from spreading.
The dust extractor contains dust
WARNING
particles that pose a risk to health.
Emptying and maintenance procedures, including the
disposal of dust containers, should only be carried out by
professionals. Suitable protective equipment is re-
quired. Do not operate the vacuum cleaner unless the
complete filter system is correctly inserted. Otherwise,
you are putting your health at risk.
Before using the equipment for the first time, check
u
that the vacuum hose is in perfect condition. Leave
the vacuum hose fitted to the vacuum cleaner while
doing this so that no dust escapes accidentally. Other-
wise, you may end up inhaling dust particles.
Do not sit on the vacuum cleaner. You can damage the
u
vacuum cleaner this way.
Take care when using the power cable and the vacuum
u
hose. Improper use of these can put other people at risk.
1 609 92A 91Y | (02.02.2024)
Do not clean the vacuum cleaner by spraying a jet of
u
water directly at it. Water entering the top of the va-
cuum cleaner will increase the risk of electric shock.
Connect the dust extractor to a properly earthed
u
power supply system. The plug socket and extension
cable must have a fully functioning protective conductor.
Products sold in GB only:
Your product is fitted with an BS 1363/A approved electric
plug with internal fuse (ASTA approved to BS 1362).
If the plug is not suitable for your socket outlets, it should be
cut off and an appropriate plug fitted in its place by an au-
thorised customer service agent. The replacement plug
should have the same fuse rating as the original plug.
The severed plug must be disposed of to avoid a possible
shock hazard and should never be inserted into a mains
socket elsewhere.
Do not use the socket on the vacuum cleaner when
u
wet vacuuming or in the humid condition. Contact with
water poses a risk of short circuit or electric shock.
Symbols
The following symbols may provide you with important in-
formation pertaining to the use of your dust extractor. Please
take note of these symbols and their meaning. Knowing what
these symbols mean will help you to use your extractor more
effectively and more safely.
Symbols and their meaning
WARNING! Read all the safety and gen-
eral instructions. Failure to observe the
safety and general instructions may res-
ult in electric shock, fire and/or serious
injury.
M Dust extractor from dust class M in ac-
M
cordance with IEC/EN 60335-2-69 for
the dry extraction of harmful dusts with
an exposure limit of ≥ 0.1 mg/m³
WARNING! The dust extractor contains
dust particles that pose a risk to
health. Emptying and maintenance
procedures, including the disposal of
dust containers, should only be carried
out by professionals. Suitable protect-
ive equipment is required. Do not oper-
ate the dust extractor unless the com-
plete filter system is correctly inser-
ted. Otherwise, you are putting your
health at risk.
Bosch Power Tools

Publicidad

loading